<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">probener</journal-id><journal-title-group><journal-title xml:lang="ru">Известия высших учебных заведений. ПРОБЛЕМЫ ЭНЕРГЕТИКИ</journal-title><trans-title-group xml:lang="en"><trans-title>Power engineering: research, equipment, technology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-9903</issn><issn pub-type="epub">2658-5456</issn><publisher><publisher-name>Kazan State Power Engineering  University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.30724/1998-9903-2022-24-3-66-82</article-id><article-id custom-type="elpub" pub-id-type="custom">probener-2227</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭНЕРГЕТИЧЕСКИЕ СИСТЕМЫ И КОМПЛЕКСЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ENERGY SYSTEMS AND COMPLEXES</subject></subj-group></article-categories><title-group><article-title>Приемы системного анализа и ресурсосберегающие электромембранные технологии при создании малосточной системы водопользования объектов энергетики Республики Татарстан</article-title><trans-title-group xml:lang="en"><trans-title>System analysis methods and resource-saving electromembrane technologies in creating a low-flow water system using of Tatarstan Republic energy facilities</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Чичиров</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Chichirov</surname><given-names>A. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Чичиров Андрей Александрович – д-р хим. наук, профессор, заведующий кафедрой «Химия и водородная энергетика»</p></bio><bio xml:lang="en"><p>Andrey A. Chichirov</p></bio><email xlink:type="simple">aachichirova@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Филимонова</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Filimonova</surname><given-names>A. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Филимонова Антонина Андреевна – канд. мед. наук, доцент кафедры «Химия и водородная энергетика»</p></bio><bio xml:lang="en"><p>Antonina A. Filimonova</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Чичирова</surname><given-names>Н. Д.</given-names></name><name name-style="western" xml:lang="en"><surname>Chichirova</surname><given-names>N. D.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Чичирова Наталия Дмитриевна – д-р химич. наук, профессор, заведующий кафедрой «Атомные и тепловые электрические станции»</p></bio><bio xml:lang="en"><p>Natalya D. Chichirova</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Минибаев</surname><given-names>А. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Minibaev</surname><given-names>A. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Минибаев Азамат Ильшатович – старший преподаватель кафедры «Атомные и тепловые электрические станции»</p></bio><bio xml:lang="en"><p>Azamat I. Minibaev</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Казанский государственный энергетический университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Kazan State Power Engineering University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>14</day><month>06</month><year>2022</year></pub-date><volume>24</volume><issue>3</issue><fpage>66</fpage><lpage>82</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Чичиров А.А., Филимонова А.А., Чичирова Н.Д., Минибаев А.И., 2022</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="ru">Чичиров А.А., Филимонова А.А., Чичирова Н.Д., Минибаев А.И.</copyright-holder><copyright-holder xml:lang="en">Chichirov A.A., Filimonova A.A., Chichirova N.D., Minibaev A.I.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.energyret.ru/jour/article/view/2227">https://www.energyret.ru/jour/article/view/2227</self-uri><abstract><sec><title>ЦЕЛЬ</title><p>ЦЕЛЬ. теоретическое обоснование ресурсосберегающих технологий и разработка «концевых» электромембранных установок при создании малосточной системы водопользования объектов энергетики Республики Татарстан.</p></sec><sec><title>МЕТОДЫ</title><p>МЕТОДЫ. В работе использовались приемы системного анализа и была разработана математическая модель для описания движения водных потоков и концентраций веществ в них. Описано задействованное оборудование, сконструированное для экспериментальной и промышленной отработки предлагаемых технологий с техническими характеристиками разработанных аппаратов и установок.</p></sec><sec><title>РЕЗУЛЬТАТЫ</title><p>РЕЗУЛЬТАТЫ. На тепловых электрических станциях по результатам проведенного системного анализа была показана возможность утилизации отходов водоподготовительных установок. Для переработки отходов испарительной водоподготовительной установки Казанской ТЭЦ-3 была реализована электромембранная технология очистки и разделения на двух последовательно соединенных аппаратах диффузионного диализа и электродиалиаза, позволяющие отделение щелочи от сточных вод и ее концентрирования. Конечными продуктами электромембранной переработки являются щелочной раствор с рН 13,86 и концентрацией ОН- ионов 2,7% (до 4%) и умягченный щелоче-солевой раствор. Присутствие солевых компонентов в щелочном растворе обнаруживается в пределах 2% по массе. Щелочной раствор может использоваться в цикле станции для регенерации анионитных фильтров I ступени. Щелоче-солевой раствор не содержит ионов жесткости и может подаваться на подпитку теплосети. Электромембранная установка позволяет перерабатывать за час 0,5 м3 щелочных отходов испарительной водоподготовительной установки. Образуются на выходе концентрированный щелочной раствор и щелоче-солевой раствор в пропорции - 1:9. Электромембранная установка потребляет 6 кВт*ч электроэнергии на переработку 1 м3 сточных вод. Работа установки характеризуется безотходностью и безреагентностью. На ионитной водоподготовительной установке Нижнекамской ТЭЦ-1 был предложен метод, разработана технология и смонтирована экспериментальная опытно-промышленная установка для переработки щелочных отработанных регенерационных растворов анионитных фильтров. Электродиализатор перерабатывает. Производительность установки составляет 1,5 м3 в час щелочных сточных вод с получением 0,15 тонн 4% щелочного раствора и потреблением электроэнергии - 4 кВт*ч на 1 м3 щелочных отработанных растворов. При работе установки отмечается полное отсутствие отходов с безреагентным процессом утилизации сточных вод.</p></sec><sec><title>ЗАКЛЮЧЕНИЕ</title><p>ЗАКЛЮЧЕНИЕ. Возврат регенерированных растворов щелочи и умягченной воды в производственный цикл позволяет получить значительное улучшение показателей, характеризующих экологичность и ресурсосбережение без использования химических реагентов.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>THE PURPOSE</title><p>THE PURPOSE. theoretical substantiation of resource-saving technologies and development of "terminal" electromembrane installations when creating a low-flow water use system for energy facilities of the Republic of Tatarstan.</p></sec><sec><title>METHODS</title><p>METHODS. In the work, the methods of system analysis were used and a mathematical model was developed to describe it. The description and technical characteristics of the developed devices and installations for testing the proposed technologies are presented.</p></sec><sec><title>RESULTS</title><p>RESULTS. At Kazan CHPP-3, a technology was developed and a pilot electromembrane plant was installed for the disposal of blowdown water from the thermal desalination complex. As a result of the operation of the electromembrane unit, a transparent alkaline solution is formed with a pH of 13.86 and a concentration of OH ions of 2.7% (up to 4%). The content of salt components in the concentrate is 2% by weight. The resulting concentrated alkaline solution can be used in the cycle of the station for the regeneration of anion exchange filters of the 1st stage. The softened saline solution is fed to the heating network. The electromembrane plant processes 0.5 tons per hour of alkaline wastewater with a ratio of concentrated alkaline solution to softened brine of 1:9. The specific power consumption is 6 kWh per 1 ton of blowdown water. The operation of the plant is characterized by the complete absence of waste and bezreagnosti. At the ion-exchange water treatment plant of the Nizhnekamsk CHPP-1, a method was proposed, a technology was developed, and an experimental pilot plant was installed for processing alkaline spent regeneration solutions of anion-exchange filters. The electromembrane plant processes 1.5 tons per hour of alkaline waste. The capacity of the plant is 0.1 tons of 4% alkaline solution. Specific power consumption - 4 kWh per 1 ton of alkaline waste solutions. During the operation of the installation, there is a complete absence of waste with a reagent-free wastewater disposal process.</p></sec><sec><title>CONCLUSION</title><p>CONCLUSION. The return of regenerated alkali solutions and softened water to the production cycle makes it possible to obtain a significant improvement in indicators that characterize environmental friendliness and resource saving without the use of chemical reagents.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>электромембранные технологии</kwd><kwd>утилизация сточных вод</kwd><kwd>ТЭС</kwd><kwd>экономия воды и реагентов</kwd></kwd-group><kwd-group xml:lang="en"><kwd>electromembrane technologies</kwd><kwd>wastewater disposal</kwd><kwd>thermal power plants</kwd><kwd>water and reagents saving</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Исследование выполнено при финансовой поддержке РНФ в рамках научного проекта «Проведение фундаментальных научных исследований малыми отдельными научными группами» № 22-29-01300</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Росводресурсы [Электронный ресурс]. Доступно по : https://voda.gov.ru/</mixed-citation><mixed-citation xml:lang="en">Rosvodresursy [Electronic resource]. Available at: https://voda.gov.ru/</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Долматов И.А. Обоснование уровня ставок платы за пользование водными объектами, находящимися в федеральной собственности, для ТЭЦ, использующих прямоточные системы технического водоснабжения: отчет о НИИР. Москва: Высшая школа экономики, 2018. 112 с.</mixed-citation><mixed-citation xml:lang="en">Dolmatov I.A. Justification of the level of fees for the use of federally owned water bodies for CHPPs using direct-flow service water supply systems: NIIR report. Moscow: Higher School of Economics. 2018. 112 p.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Печников А.Ф, Шупарский А.И. Образование и утилизация токсичных отходов тепловых электростанций // Электрические станции. 2001. №4. С. 19-20.</mixed-citation><mixed-citation xml:lang="en">Pechnikov A.F., Shuparsky A.I. Formation and utilization of toxic wastes of thermal power plants // Electric stations. 2001;4:19-20.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang C., Zhong L., Fu X., Wang J., Wu Z. Revealing water stress by the thermal power industry in China based on a high spatial resolution water withdrawal and consumption inventory // Environ. Sci. Technol. 2016. №50 (4). Р. 1642−1652.</mixed-citation><mixed-citation xml:lang="en">Zhang C., Zhong L., Fu X., Wang J., Wu Z. Revealing water stress by the thermal power industry in China based on a high spatial resolution water output and consumption inventory // Environ. sci. Technol. 2016;50 (4):1642−1652.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Бойко Н.И., Одарюк В.А., Сафонов А.В. Основные направления безотходных и малоотходных технологий // Технологии гражданской безопасности. 2015. Т.12. № 1 (43). С. 68-72.</mixed-citation><mixed-citation xml:lang="en">Boyko N.I., Odaryuk V.A., Safonov A.V. The main directions of non-waste and low-waste technologies // Civil Security Technologies. 2015;12;1(43):68-72.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Salgot M., Folch M. Wastewater treatment and water reuse // Curr. Opin. Environ. Sci. Heal. 2018. №2. Р. 64–74.</mixed-citation><mixed-citation xml:lang="en">Salgot M., Folch M. Wastewater treatment and water reuse // Curr. Opin. Environ. sci. Heal. 2018;2:64–74.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Yaqub M., Lee W. Zero-liquid discharge (ZLD) technology for resource recovery from wastewater: A review // Science of the total environment. 2019. №681. Р. 551 –563.</mixed-citation><mixed-citation xml:lang="en">Yaqub M., Lee W. Zero-liquid discharge (ZLD) technology for resource recovery from wastewater: A review // Science of the total environment. 2019;681:551–563.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Закиров И.А., Королев А.Г., Чичирова Н.Д., Чичиров А.А., Власов С.М., Паймин С.С.Ресурсосберегающие технологии при создании замкнутых систем водопользования на ТЭС //Известия высших учебных заведений. Проблемы энергетики. 2013. № 11-12. С. 55-60.</mixed-citation><mixed-citation xml:lang="en">Zakirov I.A., Korolev A.G., Chichirova N.D., Chichirov A.A., Vlasov S.M., Paimin S.S. Resource-saving technologies in the creation of closed water use systems at thermal power plants // News of higher educational institutions. Energy problems. 2013; 11-12: 55-60.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Филимонова А.А. Электромембранные технологии в теплоэнергетике и промышленности // Мембраны и мембранные технологии. 2020. Т. 10. № 4. С. 237-248.</mixed-citation><mixed-citation xml:lang="en">Filimonova A.A. Electromembrane technologies in heat power engineering and industry // Membranes and membrane technologies. 2020;4:237-248.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Handojo L. Electro-membrane processes for organic acid recovery // RSC Adv. 2019. № 9. Р. 7854 –7869.</mixed-citation><mixed-citation xml:lang="en">Handojo L. Electro-membrane processes for organic acid recovery // RSC Adv. 2019; 9:7854–7869.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Reig M. Selectrodialysis and bipolar membrane electrodialysis combination for industrial process brines treatment: monovalent-divalent ions separation and acid and base production // Desalination. 2016. №399. Р. 88–95.</mixed-citation><mixed-citation xml:lang="en">Reig M. Selectrodialysis and bipolar membrane electrodialysis combination for industrial process brines treatment: monovalent-divalent ions separation and acid and base production // Desalination. 2016;399:88–95.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Scarazzato T. Water reclamation and chemicals recovery from a novel cyanide-free copper plating bath using electrodialysis membrane process // Desalination. 2018. №436. Р. 114–124.</mixed-citation><mixed-citation xml:lang="en">Scarazzato T. Water reclamation and chemicals recovery from a novel cyanide-free copper plating bath using electrodialysis membrane process // Desalination. 2018;436:114–124.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Ward A.J. Nutrient recovery from wastewater through pilot scale electrodialysis // Water Res. 2018. №135. Р. 57–65.</mixed-citation><mixed-citation xml:lang="en">Ward A.J. Nutrient recovery from wastewater through pilot scale electrodialysis // Water Res. 2018;135:57–65.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Патент 2666425 С2 РФ. Способ снижения карбонатной жесткости воды и устройство для этого / А.М. Фридкин, Н.Р. Гребенщиков, А.В. Пименов, В.М. Сафин, М.М. Бубнов, М.И. Серушкин // Изобретения. Полезные модели. 2018. №25.</mixed-citation><mixed-citation xml:lang="en">Patent 2666425 C2 RF. A method for reducing the carbonate hardness of water and a device for this / A.M. Fridkin, N.R. Grebenshchikov, A.V. Pimenov, V.M. Safin, M.M. Bubnov, M.I. Serushkin. Inventions. Useful models. 2018;25.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Антонов А.А., Михайленко В.Г. Очистка промышленных стоков методом электромембранного умягчения // В сборнике: Экология и рациональное природопользование агропромышленных регионов. Сборник докладов III Международной молодежной научной конференции. Белгород, 2015. С. 17-19.</mixed-citation><mixed-citation xml:lang="en">Antonov A.A., Mikhailenko V.G. Purification of industrial wastewater by the method of electromembrane softening // In the collection: Ecology and rational environmental management of agro-industrial regions. Collection of reports of the III International Youth Scientific Conference. Belgorod, 2015;17-19.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Breytus A. Ion exchange membrane adsorption in Donnan dialysis // Separation and Purification Technology. 2019. №226. Р. 252–258.</mixed-citation><mixed-citation xml:lang="en">Breytus A. Ion exchange membrane adsorption in Donnan dialysis // Separation and Purification Technology. 2019;226:252–258.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Camacho L.M. Optimization of electrodialysis metathesis (EDM) desalination using factorial design methodology // Desalination. 2017. №403. Р. 136–143.</mixed-citation><mixed-citation xml:lang="en">Camacho L.M. Optimization of electrodialysis metathesis (EDM) desalination using factorial design methodology // Desalination. 2017;403:136–143.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Pedersen-Bjergaarda S. Electromembrane extraction–Recent trends and where to go // Journal of pharmaceutical analysis. 2017. №7. Р. 141–147.</mixed-citation><mixed-citation xml:lang="en">Pedersen-Bjergaarda S. Electromembrane extraction–Recent trends and where to go // Journal of pharmaceutical analysis. 2017;7:141–147.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang Y.F., Liu L., Du J., Fu R., Van der Bruggen B., Zhang Y. Fracsis: ion fractionation and metathesis by a NF-ED integrated system to improve water recovery // J. Membr. Sci. 2017. №523. Р. 385–393.</mixed-citation><mixed-citation xml:lang="en">Zhang Y.F., Liu L., Du J., Fu R., Van der Bruggen B., Zhang Y. Fracsis: ion fractionation and metathesis by a NF-ED integrated system to improve water recovery. J. Membr. sci. 2017;523:385–393.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Davis J.R., Chen Y., Baygents J.C., Farrell J. Production of acids and bases for ion exchange regeneration from dilute salt solutions using bipolar membrane electrodialysis // ACS Sustainable Chem. Eng. 2015. №3 (9). Р. 2337−2342.</mixed-citation><mixed-citation xml:lang="en">Davis J.R., Chen Y., Baygents J.C., Farrell J. Production of acids and bases for ion exchange regeneration from dilute salt solutions using bipolar membrane electrodialysis // ACS Sustainable Chem. Eng. 2015;3(9):2337−2342.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Tian W., Wang X., Fan C., Cui Z. Optimal treatment of hypersaline industrial wastewater via bipolar membrane electrodialysis // ACS Sustainable Chem. Eng. 2019. №7. Р. 12358−12368.</mixed-citation><mixed-citation xml:lang="en">Tian W., Wang X., Fan C., Cui Z. Optimal treatment of hypersaline industrial wastewater via bipolar membrane electrodialysis. ACS Sustainable Chem. Eng. 2019;7:12358−12368.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang J., Niu D., Zhang X., Hu S. An economical process to recover sulfuric acid and tetrabutylammonium ions from acidic saline wastewater with organics // Desalin. Water Treat. 2018. №129. Р. 149−159.</mixed-citation><mixed-citation xml:lang="en">Zhang J., Niu D., Zhang X., Hu S. An economical process to recover sulfuric acid and tetrabutylammonium ions from acidic saline wastewater with organics // Desalin. water treatment. 2018;129:149−159.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Koter S. Transport of simple electrolyte solutions through ion-exchange membranes – the capillary model // J. Memb. Sci. 2002. № 206 (1-2). Р. 201-215.</mixed-citation><mixed-citation xml:lang="en">Koter S. Transport of simple electrolyte solutions through ion-exchange membranes – the capillary model. J. Memb. sci. 2002;206(1-2):201-215.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Bejanidze I., Pohrebennyk V., Kharebava T., Koncelidze L., Jun S. Сorrection of the chemical composition of the washing waters received as a result of Н- cation exchange of ionexchange resin // International Multidisciplinary Scientific GeoConference, SGEM, Sofia. 2019. №19. P. 133-140.</mixed-citation><mixed-citation xml:lang="en">Bejanidze I., Pohrebennyk V., Kharebava T., Koncelidze L., Jun S. Correction of the chemical composition of the washing waters received as a result of Н-cation exchange of ion-exchange resin. International Multidisciplinary Scientific GeoConference, SGEM, Sofia. 2019;19:133-140.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Филимонова А.А., Чичиров А.А., Чичирова Н.Д. Утилизация жидких высокоминерализованных отходов химобессоливающей водоподготовительной установки ТЭС с генерацией электроэнергии методом обратного электродиализа // Мембраны и мембранные технологии. 2021. Т. 11. № 5. С. 382-390.</mixed-citation><mixed-citation xml:lang="en">Filimonova A.A., Chichirov A.A., Chichirova N.D. Utilization of highly mineralized liquid wastes of a chemically desalinated water treatment plant at a thermal power plant with electricity generation by reverse electrodialysis. Membrans and membrane technologies. 2021;5:382-390.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Mei Y., Tang C.Y. Recent developments and future perspectives of reverse electrodialysis technology: A review // Desalination. 2018. №425. Р. 156–174.</mixed-citation><mixed-citation xml:lang="en">Mei Y., Tang C.Y. Recent developments and future perspectives of reverse electrodialysis technology: A review. Desalination. 2018;425:156–174.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Rijnaarts T., Moreno J., Saakes M., deVos W.M., Nijmeijer K. Role of anion exchange membrane fouling in reverse electrodialysis using natural feed waters // Colloids and Surfaces A. 2019. № 560. Р. 198–204.</mixed-citation><mixed-citation xml:lang="en">Rijnaarts T., Moreno J., Saakes M., deVos W.M., Nijmeijer K. Role of anion exchange membrane fouling in reverse electrodialysis using natural feed waters. Colloids and Surfaces A. 2019;560:198–204 .</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Gioli P., Silingardi G.E., Ghiglio G. High quality water from refinery waste // Desalination. 1987. №67. Р. 271-282.</mixed-citation><mixed-citation xml:lang="en">Gioli P., Silingardi G.E., Ghiglio G. High quality water from refinery waste. Desalination. 1987;67:271-282.</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Вафин Т.Ф., Чичирова Н.Д., Чичиров А.А., Закиров И.А. Технологические схемы утилизации стоков водоподготовительных испарительных установок с использованием электромембранных аппаратов // Известия высших учебных заведений. Проблемы энергетики. 2012. № 1-2. С. 182-186.</mixed-citation><mixed-citation xml:lang="en">Vafin T.F., Chichirova N.D., Chichirov A.A., Zakirov I.A. Technological schemes for the utilization of wastewater from water treatment evaporative plants using electromembrane devices. Izvestia of higher educational institutions. Energy problems. 2012;1-2:182-186.</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Седлов А.С. Исследование и отработка процесса использования продувочной воды многоступенчатой испарительной установки в цикле водоподготовки // Теплоэнергетика. 1991. №7. С. 22-26.</mixed-citation><mixed-citation xml:lang="en">Sedlov A.S. Research and development of the process of using blowdown water of a multistage evaporation plant in the water treatment cycle. Thermal Engineering. 1991; 7:22-26.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
