<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">probener</journal-id><journal-title-group><journal-title xml:lang="ru">Известия высших учебных заведений. ПРОБЛЕМЫ ЭНЕРГЕТИКИ</journal-title><trans-title-group xml:lang="en"><trans-title>Power engineering: research, equipment, technology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-9903</issn><issn pub-type="epub">2658-5456</issn><publisher><publisher-name>Kazan State Power Engineering  University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.30724/1998-9903-2022-24-5-61-73</article-id><article-id custom-type="elpub" pub-id-type="custom">probener-2416</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭЛЕКТРОТЕХНИЧЕСКИЕ КОМПЛЕКСЫ И СИСТЕМЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ELECTROTECHNICAL COMPLEXES AND SYSTEMS</subject></subj-group></article-categories><title-group><article-title>Анализ парка и оценка коммутационного ресурса выключателей 10 кВ филиала ПАО «Россети центр» - «Орелэнерго»</article-title><trans-title-group xml:lang="en"><trans-title>Analysis of the fleet and evaluation of the switching resource of 10 kv switches of the branch of pjsc «Rosseti Center»-«Orelenergo»</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Виноградов</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Vinogradov</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Виноградов Александр Владимирович – д-р техн. наук, доцент, заведующий лабораторией электроснабжения и теплообеспечения </p><p>г. Москва</p></bio><bio xml:lang="en"><p>Alexander V. Vinogradov </p><p>Moscow</p></bio><email xlink:type="simple">winaleksandr@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Лансберг</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Lansberg</surname><given-names>A. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Лансберг Александр Александрович – инженер отдела энергосбережения и повышения энергоэффективности филиала</p><p>г. Орел</p></bio><bio xml:lang="en"><p>Alexander A. Lansberg – the branch </p><p>Orel</p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБНУ «Федеральный научный агроинженерный центр ВИМ»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>FGBNU «Federal Scientific Agroengineering Center VIM»</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Филиал ПАО «Россети Центр»-«Орелэнерго»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Filial PJSC «Rosseti Center»-«Orelenergo»</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>08</day><month>12</month><year>2022</year></pub-date><volume>24</volume><issue>5</issue><fpage>61</fpage><lpage>73</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Виноградов А.В., Лансберг А.А., 2022</copyright-statement><copyright-year>2022</copyright-year><copyright-holder xml:lang="ru">Виноградов А.В., Лансберг А.А.</copyright-holder><copyright-holder xml:lang="en">Vinogradov A.V., Lansberg A.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.energyret.ru/jour/article/view/2416">https://www.energyret.ru/jour/article/view/2416</self-uri><abstract><p>ЦЕЛЬ. Анализ парка и оценка коммутационного ресурса выключателей 10 кВ филиала ПАО «Россети Центр»-«Орелэнерго». МЕТОДЫ. В работе на основе базы данных филиала ПАО «Россети Центр»-«Орелэнерго» был произведен анализ парка высоковольтных выключателей 10 кВ, выявлены типы применяемых выключателей, их доли в составе парка выключателей. Исследован парк выключателей по техническим характеристикам, в том числе номинальным токам и токам предельной отключающей способности в соответствии с ГОСТ Р 52565-2006 и ГОСТ 687-78, а также действующими стандартами технической организации ПАО «Россети». РЕЗУЛЬТАТЫ. В ходе исследования было выявлено, что парк выключателей 10 кВ, установленных в распределительных устройствах подстанций с высшим напряжением 35-110 кВ филиала ПАО «Россети Центр»-«Орелэнерго» представлен 1833 коммутационными аппаратами, среди которых: 1197 выключателей c маломасляными дугогасительными камерами, 636 выключателей – с вакуумными, что составляет, соответственно 65% и 35% парка. При этом 1009 коммутационных аппаратов имеют номинальный ток 630 А, а 366 коммутационных аппаратов – 1000 А, 1526 единиц оборудования имеет номинальный ток отключения 20 кА. Выполнено сравнение маломасляного выключателя типа ВМП и вакуумного выключателя ВВВ с современным вакуумным выключателем серии BB/TEL с точки зрения коммутационного ресурса с целью обоснования его применения для замены указанных выключателей на конкретных линиях электропередачи. ВЫВОДЫ. Выявление параметров парка выключателей 10 кВ позволяет разрабатывать рациональные планы по замене оборудования. Анализ коммутационного ресурса разных типов выключателей позволяет выбирать оборудование с лучшими характеристиками.</p></abstract><trans-abstract xml:lang="en"><p>THE PURPOSE. Analysis of the fleet and evaluation of the switching resource of 10 kV switches of the branch of PJSC «Rosseti Center»-«Orelenergo». METHODS. In the work, based on the database of the branch of PJSC «Rosseti Center»-«Orelenergo», an analysis of the fleet of 10 kV high-voltage switches was carried out, the types of switches used, their shares in the fleet of switches were identified. The park of circuit breakers was investigated according to technical characteristics, including rated currents and currents of maximum breaking capacity in accordance with GOST R 52565-2006 and GOST 687-78, as well as the current standards of the technical organization of PJSC «Rosseti». RESULTS. In the course of the study, it was revealed that the fleet of 10 kV switches installed in switchgear substations with a higher voltage of 35-110 kV of the branch of PJSC «Rosseti Center»-«Orelenergo» is represented by 1833 switching devices, among which: 1197 switches with low-oil arc extinguishing chambers, 636 switches with vacuum, which is, respectively, 65% and 35% of the park. At the same time, 1009 switching devices have a rated current of 630 A, and 366 switching devices – 1000 A, 1526 pieces of equipment have a rated cut-off current of 20 kA. A comparison of a low-oil switch of the VMP type and a vacuum switch BBB with a modern vacuum switch of the BB/TEL series from the point of view of the switching resource in order to justify its use to replace these switches on specific power lines. CONCLUSIONS. Identification of the parameters of the 10 kV circuit breaker fleet makes it possible to develop rational plans for equipment replacement. Analysis of the switching resource of different types of switches allows you to choose equipment with the best characteristics.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>парк выключателей 10 кВ</kwd><kwd>высоковольтный выключатель</kwd><kwd>коммутационный ресурс</kwd><kwd>отключающая способность</kwd></kwd-group><kwd-group xml:lang="en"><kwd>10 kV switch park</kwd><kwd>high-voltage switch</kwd><kwd>switching resource</kwd><kwd>breaking capacity</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Seung-Bok Choi, Fauziah Shahul Hamid and Liyuan Han. Research on High Voltage Circuit Breaker Mechanical Faults Online Monitoring // Applied Mechanics and Materials. 2014. Volume 521, pp. 362-365. https://doi.org/10.4028/www.scientific.net/AMM.521.362.</mixed-citation><mixed-citation xml:lang="en">Seung-Bok Choi, Fauziah Shahul Hamid and Liyuan Han. Research on High Voltage Circuit Breaker Mechanical Faults Online Monitoring. Applied Mechanics and Materials. 2014. Volume 521, pp. 362-365. https://doi.org/10.4028/www.scientific.net/AMM.521.362.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Guishu Liang, Hejin Yuan, and Baoshu Li. A Fault Diagnosis Method of High Voltage Circuit Breaker Based on Moving Contact Motion Trajectory and ELM // Mathematical Problems in Engineering. 2016.</mixed-citation><mixed-citation xml:lang="en">Guishu Liang, Hejin Yuan, and Baoshu Li. A Fault Diagnosis Method of High Voltage Circuit Breaker Based on Moving Contact Motion Trajectory and ELM. Mathematical Problems in Engineering. 2016.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Yang Z.-Z., Xu J.-Y, Li B., Liu Y. Design of monitoring system for mechanical status of high voltage vacuum circuit breaker // High Voltage Apparatus. 2013. V. 49, no. 8, pp. 26–34.</mixed-citation><mixed-citation xml:lang="en">Yang Z.-Z., Xu J.-Y, Li B., Liu Y. Design of monitoring system for mechanical status of high voltage vacuum circuit breaker. High Voltage Apparatus. 2013. V. 49, no. 8, pp. 26–34.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Chen J., Hu Z., Su X. Key technology design to on-line monitoring of mechanical characteristics for intelligent vacuum circuit breaker // High Voltage Apparatus. 2014. V. 50, No. 4, pp. 108–112.</mixed-citation><mixed-citation xml:lang="en">Chen J., Hu Z., Su X. Key technology design to on-line monitoring of mechanical characteristics for intelligent vacuum circuit breaker. High Voltage Apparatus. 2014;50(4):108– 112.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Tahir Midhat Lazimov, Samir Ali Huseyn Akhundov. Research on Influence of HighVoltage Circuit Breakers’ Characteristics on Switching Overvoltages and Overcurrents. Conference: Third International Conference on Electrical and Electronics Engineering, ELECO- 2003At: Bursa, Turkey. DOI:10.13140/RG.2.1.4216.7205.</mixed-citation><mixed-citation xml:lang="en">Tahir Midhat Lazimov, Samir Ali Huseyn Akhundov. Research on Influence of HighVoltage Circuit Breakers’ Characteristics on Switching Overvoltages and Overcurrents. Conference: Third International Conference on Electrical and Electronics Engineering, ELECO- 2003At: Bursa, Turkey. doi:10.13140/RG.2.1.4216.7205.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Андреев Д.А., Назарычев И.А. Анализ методов оценки коммутационного ресурса высоковольтных выключателей // Вестник Ивановского государственного энергетического университета. № 2. 2008. С. 69-84.</mixed-citation><mixed-citation xml:lang="en">Andreev D.A., Nazarychev I.A. Analysis of methods for estimating the switching resource of high-voltage switches. Bulletin of the Ivanovo State Power Engineering University.. 2008;2:69-84.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Балаков Ю.Н., Шунтов А.В. О фактическом коммутационном ресурсе выключателей // Энергобезопасность и энергосбережение. №6. 2009. С. 35-38.</mixed-citation><mixed-citation xml:lang="en">Balakov Yu.N., Shuntov A.V. On the actual switching resource of switches. Energy security and energy conservation. 2009;6:35-38.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Муссонов Г.П., Снопкова Н.Ю., Гаврилов А.В. Учет величины коммутируемого тока для определения остаточного коммутационного ресурса высоковольтных выключателей // Вестник Иркутского государственного технического университета. 2014. №12 (95). С. 205-210.</mixed-citation><mixed-citation xml:lang="en">Monsonov G.P., Snopkova N.Yu., Gavrilov A.V. Taking into account the magnitude of the switched current to determine the residual switching resource of high-voltage switches. Bulletin of Irkutsk State Technical University. 2014;12 (95):205-210.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Виноградов А.В., Бородин М.В., Лансберг А.А., Псарев А.И., Сорокин Н.С. Анализ типов высоковольтных коммутационных аппаратов и оценка остаточного ресурса выключателей, установленных на подстанциях с высшим напряжением 35-110 кВ филиала ПАО «МРСК Центра»-«Орелэнерго» // Вестник Казанского государственного энергетического университета. 2021. Т. 13. №1 (49). С. 118-127.</mixed-citation><mixed-citation xml:lang="en">Vinogradov A.V., Borodin M.V., Lansberg A.A., Psarev A.I., Sorokin N.S. Analysis of types of high-voltage switching devices and evaluation of the residual life of switches installed at substations with a higher voltage of 35-110 kV of the branch of PJSC IDGC of Centre-Orelenergo. Bulletin of the Kazan State Energy University. 2021;13:1 (49):118-127.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">ВВ/TEL. Вакуумный выключатель. Руководство по эксплуатации. Доступно по: https://www.tavrida.com/upload/iblock/1db/ter_vcb15_booklet.pdf. Ссылка активна на 11.12.2021.</mixed-citation><mixed-citation xml:lang="en">BB/TEL. Vacuum circuit breaker. Operation manual. Available at: https://www.tavrida.com/upload/iblock/1db/ter_vcb15_booklet.pdf. Accessed: 11.12.2021.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Виноградов А.В., Капитонов А.И., Лансберг А.А., Сорокин Н.С., Фомин И.Н. Определение токов коротких замыканий в сельской электрической сети 10 кВ, секционируемой реклоузерами для осуществления дистанционного контроля их срабатывания // Вестник аграрной науки Дона. 2021. № 1 (53). С. 34-43.</mixed-citation><mixed-citation xml:lang="en">Vinogradov A.V., Kapitonov A.I., Lansberg A.A., Sorokin N.S., Fomin I.N. Determination of short-circuit currents in a rural 10 kV electrical network sectioned by reclosers for remote monitoring of their operation. Bulletin of Agrarian Science of the Don. 2021;1 (53):34- 43.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">ВВВ-10-2/320У2. Электрические сети. Доступно по: https://leg.co.ua/info/vyklyuchateli/vvv-10-2/320u2.html. Ссылка активна на: 12.12.2021.</mixed-citation><mixed-citation xml:lang="en">BBB-10-2/320 U2. Electrical networks. Available at: https://leg.co.ua/info/vyklyuchateli/vvv-10-2/320u2.html. Accessed: 12.12.2021.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Эксплуатация выключателей ВПМ-10. Электрические Сети. Служба подстанций. Доступно по: https://www.ruscable.ru/doc/documentation/instruction-32.html. Ссылка активна на: 05.12.2021.</mixed-citation><mixed-citation xml:lang="en">Operation of VPM-10 switches. Electrical Networks. Substation service. Available at: https://www.ruscable.ru/doc/documentation/instruction-32.html. Accessed: 05.12.2021.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Раздел I. Первичное оборудование, материалы и системы, допущенные к применению на объектах ПАО «Россети» на 04.09.2020. Доступно по: http://www.rosseti.ru/investment/science/attestation/doc/razdel_I_04.09.2020.pdf. Ссылка активна на: 29.09.2020.</mixed-citation><mixed-citation xml:lang="en">Section I. Primary equipment, materials and systems approved for use at the facilities of PJSC ROSSETI on 04.09.2020. Available at: http://www.rosseti.ru/investment/science/attestation/doc/razdel_I_04.09.2020.pdf. Accessed: 09.09.2020.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
