<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">probener</journal-id><journal-title-group><journal-title xml:lang="ru">Известия высших учебных заведений. ПРОБЛЕМЫ ЭНЕРГЕТИКИ</journal-title><trans-title-group xml:lang="en"><trans-title>Power engineering: research, equipment, technology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-9903</issn><issn pub-type="epub">2658-5456</issn><publisher><publisher-name>Kazan State Power Engineering  University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.30724/1998-9903-2023-25-5-20-29</article-id><article-id custom-type="elpub" pub-id-type="custom">probener-2815</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>МЕТОДЫ И ПРИБОРЫ КОНТРОЛЯ И ДИАГНОСТИКИ МАТЕРИАЛОВ, ИЗДЕЛИЙ, ВЕЩЕСТВ И ПРИРОДНОЙ СРЕДЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>METHODS AND DEVICES FOR CONTROLLING AND DIAGNOSING MATERIALS, ARTICLES, SUBSTANCES AND NATURAL ENVIRONMENT</subject></subj-group></article-categories><title-group><article-title>Исследование работы полимерного изолятора при увлажнении искусственным туманом</article-title><trans-title-group xml:lang="en"><trans-title>Study of operation of a polymer insulator under uniform and non-uniform contamination</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Зарипов</surname><given-names>Д. К.</given-names></name><name name-style="western" xml:lang="en"><surname>Zaripov</surname><given-names>D. K.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Зарипов Дамир Камилевич – канд. техн. наук, доцент кафедры «Электрические станции» им. В.К. Шибанова (ЭС)</p><p>г. Казань</p></bio><bio xml:lang="en"><p>Kazan</p></bio><email xlink:type="simple">dzaripov@list.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Насибуллин</surname><given-names>Р. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Nasibullin</surname><given-names>R. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Насибуллин Рустем Анасович - канд. техн. наук, ведущий инженер-электроник</p><p>г. Красногорск</p></bio><bio xml:lang="en"><p>Krasnogorsk</p></bio><email xlink:type="simple">nasrus@yandex.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Закиров</surname><given-names>Д. Ф.</given-names></name><name name-style="western" xml:lang="en"><surname>Zakirov</surname><given-names>D. F.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Закиров Динар Файзелханович – аспирант</p><p>г. Казань</p></bio><bio xml:lang="en"><p>Kazan</p></bio><email xlink:type="simple">qwerty2014dinar@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Захаров</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Zakharov</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Захаров Артем Владимирович – аспирант</p><p>г. Казань</p></bio><bio xml:lang="en"><p>Kazan</p></bio><email xlink:type="simple">koktel42@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Казанский государственный энергетический университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Kazan State Power Engineering University</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ПАО «Красногорский завод им. С.А. Зверева»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>PJS Company «Krasnogorskij zavod im. S.A. Zvereva»</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2023</year></pub-date><pub-date pub-type="epub"><day>12</day><month>01</month><year>2024</year></pub-date><volume>25</volume><issue>5</issue><fpage>20</fpage><lpage>29</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Зарипов Д.К., Насибуллин Р.А., Закиров Д.Ф., Захаров А.В., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Зарипов Д.К., Насибуллин Р.А., Закиров Д.Ф., Захаров А.В.</copyright-holder><copyright-holder xml:lang="en">Zaripov D.K., Nasibullin R.A., Zakirov D.F., Zakharov A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.energyret.ru/jour/article/view/2815">https://www.energyret.ru/jour/article/view/2815</self-uri><abstract><p> АКТУАЛЬНОСТЬ. Подвесные изоляторы, техническое состояние которых в значительной мере определяет надёжность электроснабжения потребителей различных категорий, являются одним из наиболее повреждаемых элементов воздушных линий электропередачи (ВЛЭП) [1-2]. Это связано в первую очередь с тем, что в процессе своей эксплуатации, изоляторы подвергаются воздействию различных климатических условий, оказывающих прямое влияние на их изоляционные свойства. Причем, наибольшее влияние атмосферные осадки, такие как дождь, туман или роса оказывают именно в сочетании с различными твердыми, жидкими и газообразными частицами, оседающими на поверхности изолятора из воздуха, и образующими слой поверхностного загрязнения. Увлажнение этого слоя повышает электропроводимость всей изоляционной конструкции ВЛЭП и уменьшает ее изоляционную способность. Изучение влияния увлажнения загрязненной поверхности подвесной изоляции на их разрядные характеристики является актуальной научной задачей и по сей день. Решение данной задачи позволит развить существующие представления о механизмах формирования и развития разрядов на загрязненной и увлажненной поверхности изоляции и сформулировать соответствующие диагностические признаки, применимые для осуществления контроля состояния подвесных изоляторов ВЛЭП. ЦЕЛЬ. Провести лабораторные исследования, направленные на изучение поведения подвесных высоковольтных полимерных изоляторов воздушных линий электропередачи при их увлажнении. Сформулировать соответствующие диагностические признаки, применимые для осуществления контроля состояния подвесных изоляционных конструкций воздушных линий электропередачи в процессе их эксплуатации. МЕТОДЫ. При решении поставленной задачи применялись экспериментальные методы исследования, заключающиеся в моделировании работы загрязнённого полимерного изолятора в атмосфере чистого тумана с применением специальной экспериментальной установки, разработанной авторами данной статьи. РЕЗУЛЬТАТЫ. В результате проведенных лабораторных исследований, путем непрерывной регистрации значений токов утечки, а также сигналов, поступающих с дистанционного датчика, были выявлены характерные при увлажнении загрязненной изоляции особенности, которые можно использовать в качестве диагностических признаков в процессе их эксплуатации.</p></abstract><trans-abstract xml:lang="en"><p>RELEVANCE. Suspended insulators, the technical condition of which largely determines the reliability of power supply to consumers of different categories, are one of the most damaged elements of overhead power transmission lines [1-2]. This is primarily due to the fact that during their operation, insulators are exposed to various climatic conditions that have a direct impact on their insulating properties. Moreover, precipitation, such as rain, fog or dew, has the greatest impact precisely in combination with various solid, liquid and gaseous particles deposited on the insulator surface from the air, and forming a layer of surface contamination. Wetting this layer increases the electrical conductivity of the entire overhead line insulation structure and reduces its insulating capacity. Study of influence of dampening of contaminated surface of suspended insulation on their discharge characteristics is an urgent scientific task. The solution of this task enables to develop the existing understanding of the mechanisms of formation and development of discharges on the contaminated and wetted surface of insulation and to formulate the appropriate diagnostic attributes applicable to control the condition of the overhead power line insulators. OBJECTIVE. To carry out laboratory research aimed at studying the behavior of suspended high-voltage polymer insulators of overhead power lines when they are moistened. To formulate appropriate diagnostic attributes applicable for control of condition of suspended insulators of overhead power lines during their operation. METHODS. At the solution of the posed problem experimental methods of research, consisting in simulation of work of the contaminated polymeric insulator in the atmosphere of a pure fog with application of the special experimental installation developed by the authors of this article were applied. RESULTS. As a result of laboratory research, by continuous registration of leakage current values, as well as signals coming from the remote sensor, characteristic features of contaminated insulator humidification were revealed, which can be used as diagnostic signs in the process of their operation.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>воздушные линии электропередачи</kwd><kwd>подвесные полимерные изоляторы</kwd><kwd>разрядные характеристики</kwd><kwd>увлажнение изоляции</kwd><kwd>диагностические признаки</kwd></kwd-group><kwd-group xml:lang="en"><kwd>overhead transmission lines</kwd><kwd>suspended polymer insulators</kwd><kwd>discharge characteristics</kwd><kwd>insulation wetting</kwd><kwd>diagnostic signs</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Обзор аварийности и травматизма в электроэнергетических системах государств-участников СНГ за 2020 год: инф. бюллетень № 21. Исполнительный комитет Электроэнергетического совета СНГ, 2021. 141 с.</mixed-citation><mixed-citation xml:lang="en">Obzor avarijnosti i travmatizma v elektroenergeticheskih sistemah gosudarstv-uchastnikov SNG za 2020 god: inf. byulleten' № 21. Ispolnitel'nyj komitet Elektroenergeticheskogo soveta SNG, 2021. 141 s.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">В России участились аварии на энергообъектах [Электронный ресурс] // Известия Iz: [cайт]. [2021]. URL: https://iz.ru/1248071/2021-11-11/v-rossii-uchastilis-avarii-na-energoobektakh (дата обращения: 25.11.2021).</mixed-citation><mixed-citation xml:lang="en">V  Rossii  uchastilis'  avarii  na energoob"ektah  [Elektronnyj  resurs]  //  Izvestiya  Iz:  [cajt].  [2021]. URL:  https://iz.ru/1248071/2021-11-11/v-rossii-uchastilis-avarii-na-energoobektakh  (data  obrashcheniya: 25.11.2021).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">A. C. Baker et al., "Insulator Selection for AC Overhead Lines With Respect to Contamination," in IEEE Transactions on Power Delivery, vol. 24, no. 3, pp. 1633-1641, July 2009, doi: 10.1109/TPWRD.2009.2024666.</mixed-citation><mixed-citation xml:lang="en">A.  C.  Baker et  al.,  "Insulator  Selection  for  AC  Overhead  Lines  With  Respect  to  Contamination," in IEEE  Transactions  on  Power  Delivery,  vol.  24,  no.  3,  pp.  1633-1641,  July  2009,  doi: 10.1109/TPWRD.2009.2024666.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">F. A. M. Rizk and S. I. Kamel, "Modelling of HVDC wall bushing flashover in nonuniform rain," in IEEE Transactions on Power Delivery, vol. 6, no. 4, pp. 1650-1662, Oct. 1991, doi: 10.1109/61.97704.</mixed-citation><mixed-citation xml:lang="en">F. A. M. Rizk and S. I. Kamel, "Modelling of HVDC wall bushing flashover in nonuniform rain," in IEEE Transactions on Power Delivery, vol. 6, no. 4, pp. 1650-1662, Oct. 1991, doi: 10.1109/61.97704.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">L. a. Insulator, "Minimum Test Requirements for Non-Ceramic Insulators," in IEEE Transactions on Power Apparatus and Systems, vol. PAS-100, no. 2, pp. 882-890, Feb. 1981, doi: 10.1109/TPAS.1981.316947.</mixed-citation><mixed-citation xml:lang="en">L. a. Insulator, "Minimum  Test  Requirements for Non-Ceramic Insulators," in IEEE  Transactions on  Power  Apparatus  and  Systems,  vol.  PAS-100,  no.  2,  pp.  882-890,  Feb.  1981,  doi: 10.1109/TPAS.1981.316947.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">R. S. Gorur et al., "Sudden flashover of nonceramic insulators in artificial contamination tests," in IEEE Transactions on Dielectrics and Electrical Insulation, vol. 4, no. 1, pp. 79-87, Feb. 1997, doi: 10.1109/94.590870.</mixed-citation><mixed-citation xml:lang="en">R. S. Gorur et al., "Sudden flashover of nonceramic insulators in artificial contamination tests," in IEEE  Transactions  on  Dielectrics  and  Electrical  Insulation,  vol.  4,  no.  1,  pp.  79-87,  Feb.  1997,  doi: 10.1109/94.590870.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Learning from Service Experience with Composite Line Insulators [Электронный ресурс] // INMR Enriching Technical Knowledge of T&amp;D Professionals: [cайт]. [2023]. URL: https://www.inmr.com/learning-from-service-experience-with-composite-line-insulators-2/</mixed-citation><mixed-citation xml:lang="en">Patent  №  2517776  RF,  MPK  G01R  31/08.  Sposob  opticheskoj  distancionnoj  diagnostiki izoliruyushchej konstrukcii / Zaripov D.K.; zayav. i patentoobl. Zaripov D.K. № 2012151785/28; zayavl. 03.12.2012;  opubl.  27.05.2014,  6  s.5.  Massomer  CORIMASS  10G+  MFM  4085  K/F  [Elektronnyj  resurs]. Rezhim dostupa: http://cdn.krohne.com/dlc/MA_CORIMASS_G_ru_72.pdf.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Патент № 2517776 РФ, МПК G01R 31/08. Способ оптической дистанционной диагностики изолирующей конструкции / Зарипов Д.К.; заяв. и патентообл. Зарипов Д.К. № 2012151785/28; заявл. 03.12.2012; опубл. 27.05.2014, 6 с.5. Массомер CORIMASS 10G+ MFM 4085 K/F [Электронный ресурс]. Режим доступа: http://cdn.krohne.com/dlc/MA_CORIMASS_G_ru_72.pdf.</mixed-citation><mixed-citation xml:lang="en">Patent  №2660754  RF,  MPK  G01R  31/08.  Svetovoj  indikator  sostoyaniya  izoliruyushchej konstrukcii  /Zaripov  D.K.  Nasibullin  R.A.,  Margulis  S.M.,  Ibragimov  R.R.,  Igtisamov  M.CH.;  zayavitel'  i patentoobladatel' OAO «Setevaya kompaniya» № 2017125424; zayavl. 14.07.2017; opubl. 09.07.2018 Byul. № 19, 10 s.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Патент №2660754 РФ, МПК G01R 31/08. Световой индикатор состояния изолирующей конструкции /Зарипов Д.К. Насибуллин Р.А., Маргулис С.М., Ибрагимов Р.Р., Игтисамов М.Ч.; заявитель и патентообладатель ОАО «Сетевая компания» № 2017125424; заявл. 14.07.2017; опубл. 09.07.2018 Бюл. № 19, 10 с.</mixed-citation><mixed-citation xml:lang="en">Patent  №  2731169  C1  RF,  MPK  G01R  31/08.  Datchik  dlya  sistemy  nepreryvnogo  kontrolya sostoyaniya  izoliruyushchih  konstrukcij:  №  2019145586:  zayavl.  30.12.2019:  opubl.  31.08.2020  /  D.  K. Zaripov, R. A. Nasibullin, R. R. Ibragimov, M. CH. Igtisamov.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Патент № 2731169 C1 РФ, МПК G01R 31/08. Датчик для системы непрерывного контроля состояния изолирующих конструкций: № 2019145586: заявл. 30.12.2019: опубл. 31.08.2020 / Д. К. Зарипов, Р. А. Насибуллин, Р. Р. Ибрагимов, М. Ч. Игтисамов.</mixed-citation><mixed-citation xml:lang="en">Zaripov, D. K. Metod distancionnoj diagnostiki vysokovol'tnoj izoliruyushchej konstrukcii / D. K. Zaripov, T. V. Lopuhova // Izvestiya vysshih uchebnyh zavedenij. Problemy energetiki. – 2006. – № 3-4. – S. 56-60. – EDN KFQJUT.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Зарипов, Д. К. Метод дистанционной диагностики высоковольтной изолирующей конструкции / Д. К. Зарипов, Т. В. Лопухова // Известия высших учебных заведений. Проблемы энергетики. – 2006. – № 3-4. – С. 56-60. – EDN KFQJUT.</mixed-citation><mixed-citation xml:lang="en">Zaripov,  D.  K.  Raspredelennaya  sistema  kontrolya  izolyacii  vozdushnyh  linij  i  podstancij  na osnove besprovodnyh datchikov emkostnogo tipa / D. K. Zaripov, R. A. Nasibullin, D. F. Zakirov // . – 2022. – № 1. – S. 8-17. – DOI 10.25791/pribor.1.2022.1314. – EDN ABQHUI.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Зарипов, Д. К. Распределенная система контроля изоляции воздушных линий и подстанций на основе беспроводных датчиков емкостного типа / Д. К. Зарипов, Р. А. Насибуллин, Д. Ф. Закиров // . – 2022. – № 1. – С. 8-17. – DOI 10.25791/pribor.1.2022.1314. – EDN ABQHUI.</mixed-citation><mixed-citation xml:lang="en">Zaripov,  D.  K. «Issledovanie  vozmozhnosti  diagnostirovaniya  izolyatorov  vozdushnyh  linij elektroperedachi v usloviyah uvlazhneniya pri ravnomernom zagryaznenii» / D. K. Zaripov, D. F. Zakirov, A. V.  Petrov // Aktual'nye  problemy  transporta  i  energetiki:  puti  ih  innovacionnogo  resheniya  :  Materialy  X Mezhdunarodnoj nauchno-prakticheskoj konferencii, Nur-Sultan, 17 marta 2022 goda</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Зарипов Д. К. Исследование возможности диагностирования изоляторов воздушных линий электропередачи в условиях увлажнения при равномерном загрязнении / Д. К. Зарипов, Д. Ф. Закиров, А. В. Петров // Актуальные проблемы транспорта и энергетики: пути их инновационного решения : Материалы X Международной научно-практической конференции, Нур-Султан, 17 марта 2022 года.</mixed-citation><mixed-citation xml:lang="en">Zaripov,  D.  K.  Issledovanie  vozmozhnosti  diagnostirovaniya  izolyatorov  vozdushnyh  linij elektroperedachi dlya preduprezhdeniya nemotivirovannyh otklyuchenij / D. K. Zaripov, D. F. Zakirov, A. V. Petrov  //  Aktual'nye  problemy  transporta  i  energetiki:  puti  ih  innovacionnogo  resheniya  :  Materialy  X Mezhdunarodnoj nauchno-prakticheskoj konferencii, Nur-Sultan, 17 marta 2022 goda.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Зарипов Д. К. Исследование возможности диагностирования изоляторов воздушных линий электропередачи для предупреждения немотивированных отключений / Д. К. Зарипов, Д. Ф. Закиров, А. В. Петров // Актуальные проблемы транспорта и энергетики: пути их инновационного решения : Материалы X Международной научно-практической конференции, Нур-Султан, 17 марта 2022 года.</mixed-citation><mixed-citation xml:lang="en">Zaripov,  D.  K.  Issledovanie  vozmozhnosti  diagnostirovaniya  girlyandy  ravnomerno zagryaznyonnyh  izolyatorov  v  usloviyah  uvlazhneniya  /  D.  K.  Zaripov,  D.  F.  Zakirov,  A.  V.  Petrov  // Aktual'nye problemy transporta i energetiki: puti ih innovacionnogo resheniya : Materialy X Mezhdunarodnoj nauchno-prakticheskoj konferencii, Nur-Sultan, 17 marta 2022 goda.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Зарипов, Д. К. Исследование возможности диагностирования гирлянды равномерно загрязнённых изоляторов в условиях увлажнения / Д. К. Зарипов, Д. Ф. Закиров, А. В. Петров // Актуальные проблемы транспорта и энергетики: пути их инновационного решения : Материалы X Международной научно-практической конференции, Нур-Султан, 17 марта 2022 года.</mixed-citation><mixed-citation xml:lang="en">V. F. Tarasenko, V. S. Kuznecov, V. A. Panarin, V. S. Skakun, E. A. Sosnin, E. H. Baksht, “Rol' strimerov  v  formirovanii  koronnogo  razryada  pri  rezko  neodnorodnom  elektricheskom  pole”,  Pis'ma  v ZHETF, 110:1 (2019), 72–77; JETP Letters, 110:1 (2019), 85–89</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">В. Ф. Тарасенко, В. С. Кузнецов, В. А. Панарин, В. С. Скакун, Э. А. Соснин, Е. Х. Бакшт, “Роль стримеров в формировании коронного разряда при резко неоднородном электрическом поле”, Письма в ЖЭТФ, 110:1 (2019), 72–77; JETP Letters, 110:1 (2019), 85–89</mixed-citation><mixed-citation xml:lang="en">В. Ф. Тарасенко, В. С. Кузнецов, В. А. Панарин, В. С. Скакун, Э. А. Соснин, Е. Х. Бакшт, “Роль стримеров в формировании коронного разряда при резко неоднородном электрическом поле”, Письма в ЖЭТФ, 110:1 (2019), 72–77; JETP Letters, 110:1 (2019), 85–89</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
