<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">probener</journal-id><journal-title-group><journal-title xml:lang="ru">Известия высших учебных заведений. ПРОБЛЕМЫ ЭНЕРГЕТИКИ</journal-title><trans-title-group xml:lang="en"><trans-title>Power engineering: research, equipment, technology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-9903</issn><issn pub-type="epub">2658-5456</issn><publisher><publisher-name>Kazan State Power Engineering  University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.30724/1998-9903-2026-28-2-122-133</article-id><article-id custom-type="elpub" pub-id-type="custom">probener-3885</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭЛЕКТРОЭНЕРГЕТИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>ELECTRICITY</subject></subj-group></article-categories><title-group><article-title>Применение преобразования Кларк для защиты от однофазных замыканий на землю</article-title><trans-title-group xml:lang="en"><trans-title>Using the Clarke transform for protection against single-phase-to-ground faults</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Куликов</surname><given-names>А. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Kulikov</surname><given-names>A. L.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Нижегородский государственный технический университет им. Р.Е. Алексеева</p></bio><bio xml:lang="en"><p>Alexander L. Kulikov</p></bio><email xlink:type="simple">inventor61@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Старшов</surname><given-names>И. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Starshov</surname><given-names>I. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Старшов Иван Сергеевич – аспирант</p></bio><bio xml:lang="en"><p>Ivan S. Starshov</p></bio><email xlink:type="simple">ivanstarsh@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Нижегородский государственный технический университет им. Р.Е. Алексеева</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Nizhny Novgorod State Technical University R.E. Alekseev (NNSTU)</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2026</year></pub-date><pub-date pub-type="epub"><day>14</day><month>06</month><year>2026</year></pub-date><volume>28</volume><issue>2</issue><fpage>122</fpage><lpage>133</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Куликов А.Л., Старшов И.С., 2026</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="ru">Куликов А.Л., Старшов И.С.</copyright-holder><copyright-holder xml:lang="en">Kulikov A.L., Starshov I.S.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.energyret.ru/jour/article/view/3885">https://www.energyret.ru/jour/article/view/3885</self-uri><abstract><p>АКТУАЛЬНОСТЬ. Однофазные замыкания на землю остаются одними из самых часто встречающихся повреждений в распределительных электрических сетях с изолированной нейтралью. Серьезную опасность для электрооборудования энергосистемы представляют дуговые перемежающиеся однофазные замыкания на землю, в связи с переходными процессами, протекающими в сети при таких повреждениях. Длительное протекание токов однофазного замыкания на землю в кабельной линии вызывает нагрев и переход в междуфазное короткое замыкание. Разработка быстродействующей и селективной релейной защиты позволит предотвратить ущерб и обеспечит надёжное электроснабжение потребителей. ЦЕЛЬ. Для повышения быстродействия защиты применяется преобразование Кларк, позволяющее объединить мгновенные значения трех фазных токов для получения информационного признака повреждения. Необходима разработка пускового органа релейной защиты от однофазных замыканий на землю с использованием преобразования Кларк и определение свойств получившегося пускового органа. МЕТОДЫ. Программный комплекс Matlab с пакетом расширения Simulink был применён для имитационного моделирования осциллограмм токов в различных режимах электрической сети с изолированной нейтралью. Результаты моделирования позволили разработать пусковой орган защиты, использующий преобразование Кларк и обладающий повышенным быстродействием. РЕЗУЛЬТАТЫ. Разработана упрощенная структурно-функциональная схема пускового органа защиты от однофазных замыканий на землю. Проведено оценочное сравнение по чувствительности с используемой в сетях релейной защитой. Чувствительность разработанного органа защиты при дуговых перемежающихся однофазных замыканиях на землю превышает аналогичные существующие технические решения. ВЫВОДЫ. Результаты исследования перспективны для создания новой защиты от однофазных замыканий на землю в сетях с изолированной нейтралью, использующей преобразование Кларк.</p></abstract><trans-abstract xml:lang="en"><p>RELEVANCE. Single-phase-to-ground faults remain one of the most common types of damage in distribution networks with isolated neutral. Arc-ing, intermittent single-phase-to-ground faults pose a serious threat to the power system's electrical equipment due to the transient processes occurring in the network during such faults. The prolonged flow of single-phase-to-ground fault currents in a cable line causes heating and can lead to a phase-to-phase short circuit. The development of high-speed and selective relay protection will prevent damage and ensure a reliable power supply to consumers. PURPOSE. To improve protection speed, the Clarke transform is applied, which combines the instantaneous values of the three phase currents to obtain an informational feature of a fault. It is necessary to develop a starting unit for single-phase-to-ground fault protection using the Clarke transform and to determine the properties of the resulting starting unit. METHODS. The Matlab software suite with the Simulink extension package was used for simulation modeling of current oscillograms under various operating conditions of an electrical network with an isolated neutral. The simulation results allowed for the development of a protection starting unit that utilizes the Clarke transform and features increased speed. RESULTS. A simplified structural and functional diagram of a starting unit for protection against single-phase-to-ground faults has been developed. A comparative sensitivity assessment was conducted with relay protection currently used in networks. The sensitivity of the developed protection unit during arc-ing intermittent single-phase-to-ground faults exceeds that of existing similar technical solutions. CONCLUSIONS. The research results are promising for creating new protection against single-phase-to-ground faults in networks with an isolated neutral, utilizing the Clarke transform.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>защита от замыкания на землю</kwd><kwd>изолированная нейтраль</kwd><kwd>преобразование Кларк</kwd><kwd>дуговое перемежающееся однофазное замыкание на землю</kwd><kwd>однофазное замыкание на землю</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Earth fault protection</kwd><kwd>isolated neutral</kwd><kwd>Clarke transform</kwd><kwd>intermittent arcing single-phase-to-ground fault</kwd><kwd>single-phase-to-ground fault</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Федотов А.И., Ахметвалеева Л.В., Басыров Р.Ш., и др. Нормирование амплитуды высших гармоник при определении фидера с однофазным замыканием на землю //Известия высших учебных заведений. Проблемы энергетики. 2020. Т. 22. №1. С.58-68.</mixed-citation><mixed-citation xml:lang="en">Fedotov A.I., Akhmetvaleeva L.V., Basyrov R.S., et al. Rating of amplitudes of high harmonics in determining feeder with single-phase ground fault. Power engineering: research, equipment, technology. 2020; 22(1):58-68. (In Russ.) doi.org/10.30724/1998-9903-2020-22-1-58-68</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Шуин В.А., Шадрикова Т.Ю., Кузьмина Н.В., и др. Многопараметрическая токовая защита от замыканий на землю в сетях 6–10 кВ с изолированной нейтралью// Вестник ИГЭУ. 2025.№1. С. 40-46.</mixed-citation><mixed-citation xml:lang="en">Shuin V.A., Shadrikova T.YU., Kuz'mina N.V., et al. Mnogoparametricheskaya tokovaya zashchita ot zamykanii na zemlyu v setyakh 6–10 kV s izolirovannoi neitral'yu// Vestnik IGEU. 2025. 1:40–46. (In Russ). doi: 10.17588/2072-2672.2018.4.020-030</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Шуин В.А., Воробьева Е.А., Добрягина О.А., и др. Способ повышения эффективности функционирования адмитансной защиты от замыканий на землю в кабельных сетях 6–10 кВ с изолированной нейтралью // Вестник ИГЭУ.2018. №4. С.58-68.</mixed-citation><mixed-citation xml:lang="en">Shuin V.A., Vorobyova E.A., Dobryagina O.A., et al. A way to increase the operating efficiency of admittance earth fault protection in 6–10 kV cable networks with isolated neutral. Vestnik IGEU. 2018; 4:20–22. (In Russ). doi: 10.17588/2072-2672.2018.4.020-030</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Куликов А.Л., Мисриханов М.Ш. Введение в методы цифровой релейной защиты высоковольтных ЛЭП. Учеб. пособие. –М.: Энергоатомиздат, 2007. –198 с.</mixed-citation><mixed-citation xml:lang="en">Kulikov A.L., Misrikhanov M.Sh. Vvedenie v metody tsifrovoi releinoi zashchity vysokovoltnykh LEP. Moscow: NTF «Energoatomizdat», 2007. (In Russ).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Куликов А.Л., Севостьянов А.А., Ильюшин П.В. Оценка искажений напряжения в системах электроснабжения промышленных предприятий // Электричество. 2024 №5. С. 32-48.</mixed-citation><mixed-citation xml:lang="en">Kulikov A.L., Sevost'yanov A.A., Il'yushin P.V. Assessment of Voltage Distortions in Power Supply Systems of Industrial Enterprises. Elektrichestvo. 2024; 5:32–48. (In Russ). doi:10.24160/0013-5380-2024-5-32-48</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Федотов А.И., Вагапов Г.В., Абдуллазянов А.Ф., и др. Цифровая система мониторинга повреждений на линиях электропередачи // Известия высших учебных заведений. Проблемы энергетики. 2021; Т.23. №1. С.146-155.</mixed-citation><mixed-citation xml:lang="en">Fedotov A.I., Vagapov G.V., Abdullazyanov A.F., et al. Digital power lines faults monitoring system. Power engineering: research, equipment, technology. 2021;23(1):146-155. (In Russ.) https://doi.org/10.30724/1998-9903-2021-23-1-146-155</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Шуин В.А. Начальные фазовые соотношения электрических величин переходного процесса при замыканиях на землю в кабельных сетях 6-10 кВ // Электричество. 1991, № 10. С.58-61.</mixed-citation><mixed-citation xml:lang="en">Shuin V.A. Nachal'nye fazovye sootnosheniya elektricheskikh velichin perekhodnogo protsessa pri zamykaniyakh na zemlyu v kabel'nykh setyakh 6-10 kV. Elektrichestvo. 1991;10:58-61.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Шуин В.А., Кутумов Ю.Д., Кузьмина Н.В., и др. Моделирование кабельных линий напряжением 6–10 кВ при расчетах переходных процессов при замыканиях на землю // Вестник ИГЭУ. 2021.№5. С. 30-40.</mixed-citation><mixed-citation xml:lang="en">Shuin V.A., Kutumov Yu.D., Kuzmina N.V., et al. Simulation study of 6–10 kV cable lines for transient processes calculation during earth faults. Vestnik IGEU. 2021; 5:30-40. (In Russ). doi: 10.17588/2072-2672.2021.5.030-040</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Куликов А.Л., Старшов И.С. Исследование диагностических параметров режима однофазных замыканий на землю в электросетях 10 кВ // Известия высших учебных заведений. Проблемы энергетики. 2025.Т.27№4.С.42-55.</mixed-citation><mixed-citation xml:lang="en">Kulikov A.L., Starshov I.S. Study of mode recognition in 10 kV cable networks for organizing protection against single-phase ground faults. Power engineering: research, equipment, technology. 2025;27(4):42-55. (In Russ.). doi:10.30724/1998-9903-2025-27-4-42-55</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Воробьева Е.А., Шуин В.А. Анализ достоверности эквивалентных моделей кабельных сетей 6-10 кВ для расчета переходных процессов при однофазных замыканиях на землю //Материалы международной научно-технической конференции: (XVIII Бенардосовские чтения); 27–29 мая 2015 г., Иваново. Иваново:ИГЭУ. С. 456–460.</mixed-citation><mixed-citation xml:lang="en">Vorobyova E.A., Shuin V.A. Analiz dostovernosti ekvivalentnykh modelei kabel'nykh setei 6-10 kV dlya rascheta perekhodnykh protsessov pri odnofaznykh zamykaniyakh na zemlyu. In: Mezhdunarodnyi nauchno-tekhnicheskaya konferentsiya: (XVIII Benardosovskie chteniya); 27–29 May 2015; Ivanovo, Russia. Ivanovo Publ.,2015. pp.456–460. (In Russ).</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Воробьева Е.А., Шуин В.А. Оценка точности эквивалентных моделей кабельных сетей 6-10 кВ для расчета переходных процессов при однофазных замыканиях на землю// Труды VI международной научно-технической конференции. Том 2. 09–13 ноября 2015 г., Иваново. Иваново:ИГЭУ. С. 63–66.</mixed-citation><mixed-citation xml:lang="en">Vorobyova E.A., Shuin V.A. Otsenka tochnosti ekvivalentnykh modelei kabel'nykh setei 6-10 kV dlya rascheta perekhodnykh protsessov pri odnofaznykh zamykaniyakh na zemlyu In: VI mezhdunarodno nauchnaya-tekhnicheskaya konferentsiya. Tom 2; 09–13 Nov 2015; Ivanovo, Russia. Ivanovo Publ.,2015. pp.63–66. (In Russ).</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Achitaev A.A., Suslov K.V., Volkova I.O., et al. Development of an algorithm for identifying single-phase ground fault conditions in cable and overhead lines in the networks with isolated neutral // Energy Reports. 2023. Vol. 9. pp. 1079-1086.</mixed-citation><mixed-citation xml:lang="en">Achitaev A.A., Suslov K.V., Volkova I.O., et al. Development of an algorithm for identifying single-phase ground fault conditions in cable and overhead lines in the networks with isolated neutral. Energy Reports. 2023;9:1079-1086. doi:10.1016/j.egyr.2023.01.046</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Toader D., Solea C., Vesa D., et al. Analysis of the possibilities of selective detection of a single line-to-ground fault in a medium voltage network with isolated neutral // Energies. 2021. Vol. 14. N21. pp. 7019.</mixed-citation><mixed-citation xml:lang="en">Toader D., Solea C., Vesa D., et al. Analysis of the possibilities of selective detection of a single line-to-ground fault in a medium voltage network with isolated neutral. Energies. 2021;14(21):7019. doi:10.3390/en14217019</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kachesov V., Lebedev A., Kitova E. Monitoring in 6–35 kV power networks, location of single-phase ground fault and detection of fault feeder // International Journal of Electrical Power &amp; Energy Systems. 2023. Vol. 152. pp. 109271-109271.</mixed-citation><mixed-citation xml:lang="en">Kachesov V., Lebedev A., Kitova E. Monitoring in 6–35 kV power networks, location of single-phase ground fault and detection of fault feeder. International Journal of Electrical Power &amp; Energy Systems. 2023;152:109271-109271. doi:10.1016/j.ijepes.2023.109271</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Шуин В.А., Гусенков А.В. Защиты от замыканий на землю в электрических сетях 6–10 кВ. М.: НТФ «Энергопрогресс», 2001. 104 с.</mixed-citation><mixed-citation xml:lang="en">Shuin V.A., Gusenkov A.V. Zashchity ot zamykanii na zemlyu v elektricheskikh setyakh 6–10 kV. Moscow: NTF «Energoprogress», 2001. (In Russ).</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Kuliński K., Heyduk A. Ground fault in medium-voltage power networks with an isolated neutral point: spectral and wavelet analysis of selected cases in an example industrial network modeled in the atp-emtp package // Energies. 2024. Vol. 17. N 7. pp. 1532.</mixed-citation><mixed-citation xml:lang="en">Kuliński K., Heyduk A. Ground fault in medium-voltage power networks with an isolated neutral point: spectral and wavelet analysis of selected cases in an example industrial network modeled in the atp-emtp package. Energies. 2024;17(7):1532. doi:10.3390/en17071532</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Борухман, В.А. Об эксплуатации селективных защит от замыканий на землю в сетях 6-10 кВ и мероприятиях по их совершенствованию // Энергетик. 2000, № 1. С. 20– 22.</mixed-citation><mixed-citation xml:lang="en">Borukhman, V.A. Ob ekspluatatsii selektivnykh zashchit ot zamykanii na zemlyu v setyakh 6-10 kV i meropriyatiyakh po ikh sovershenstvovaniyu. Energetik. 2000; 1:20–22. (In Russ).</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Maksimova M.N., Antonov V.I., Soldatov A.V., et al. Сonversion of intermittent arc fault currents to information signals for phase-to-ground fault protection // Power Technology and Engineering. 2022. Vol. 56. N2. pp. 290-294.</mixed-citation><mixed-citation xml:lang="en">Maksimova M.N., Antonov V.I., Soldatov A.V., et al. Сonversion of intermittent arc fault currents to information signals for phase-to-ground fault protection. Power Technology and Engineering. 2022;56(2):290-294. doi: 10.1007/s10749-023-01508-w</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Лихачёв Ф.А. Замыкания на землю в сетях с изолированной нейтралью и с компенсацией емкостных токов. М.: Энергия, 1971. 152 с.</mixed-citation><mixed-citation xml:lang="en">Likhachev F.A. Zamykaniya na zemlyu v setyakh s izolirovannoi neitral'yu i s kompensatsiei emkostnykh tokov. Moscow: Energiya, 1971. (In Russ).</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
