<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">probener</journal-id><journal-title-group><journal-title xml:lang="ru">Известия высших учебных заведений. ПРОБЛЕМЫ ЭНЕРГЕТИКИ</journal-title><trans-title-group xml:lang="en"><trans-title>Power engineering: research, equipment, technology</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-9903</issn><issn pub-type="epub">2658-5456</issn><publisher><publisher-name>Kazan State Power Engineering  University</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.30724/1998-9903-2018-20-3-4-3-10</article-id><article-id custom-type="elpub" pub-id-type="custom">probener-561</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ЭНЕРГЕТИКА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>POWER ENGINEERING</subject></subj-group></article-categories><title-group><article-title>СРАВНИТЕЛЬНАЯ ОЦЕНКА ДОЛИ УДАРОВ МОЛНИЙ В ОПОРЫ И ВЕРХНИЙ ФАЗНЫЙ ПРОВОД В ПРОЛЁТЕ ВЛ БЕЗ МОЛНИЕЗАЩИТНОГО ТРОСА</article-title><trans-title-group xml:lang="en"><trans-title>COMPARATIVE ESTIMATE OF THE PROPORTION OF LIGHTNING STRIKES IN THE TOWERS AND THE UPPER PHASE WIRE IN THE SPAN OF THE OVERHEAD POWER LINES WITHOUT GROUND WIRE</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Юдицкий</surname><given-names>Д. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Yuditsky</surname><given-names>D. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>руководитель проектно-исследовательского центра ООО «НПК «Силеста»</p></bio><bio xml:lang="en"><p>Research and production company Silesta Ltd</p></bio><email xlink:type="simple">yuditskiydm@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Усачев</surname><given-names>А. Е.</given-names></name><name name-style="western" xml:lang="en"><surname>Usachev</surname><given-names>A. E.</given-names></name></name-alternatives><bio xml:lang="ru"><p>д-р физ.-мат. наук, профессор, профессор кафедры «Электрические станции им.  В.К. Шибанова» (ЭС) «Казанского государственного энергетического университета (КГЭУ)</p></bio><bio xml:lang="en"><p>State Educational Institution "Kazan State Power EngineeringUniversity", chair «Power Stations», Professor, Doctor of Physics and Mathematics</p></bio><email xlink:type="simple">aleksandr_usachev@rambler.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ООО «НПК «Силеста»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>OOO NPK Silesta</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Казанский государственный энергетический университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Kazan State Power Engineering University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2018</year></pub-date><pub-date pub-type="epub"><day>25</day><month>05</month><year>2018</year></pub-date><volume>20</volume><issue>3-4</issue><fpage>3</fpage><lpage>10</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Юдицкий Д.М., Усачев А.Е., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Юдицкий Д.М., Усачев А.Е.</copyright-holder><copyright-holder xml:lang="en">Yuditsky D.M., Usachev A.E.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.energyret.ru/jour/article/view/561">https://www.energyret.ru/jour/article/view/561</self-uri><abstract><p>В статье проводится анализ относительной доли ударов молний в опоры и верхний фазный провод пролёта воздушной линии электропередачи без молниезащитного троса, выполненный в соответствии с различными действующими в Российской Федерации нормативными  документами по молниезащите. Показываются существенные различия результатов оценок по  разным методикам.</p></abstract><trans-abstract xml:lang="en"><p>In the article the analysis of the proportion of lightning strikes in the towers and the upper phase wire of the span of overhead transmission lines without ground wire, made in accordance with different applicable in the Russian Federation, regulatory documents of lightning. Built zone protection of the towers on transmission lines lines without ground wire depending on the span length and the height of the towers. Seem significant differences of the results of assessments by different techniques. The results of the builds were revealed the need to refine existing methods to determine the fraction of lightning strikes in the towers and phase wirles.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>молниезащита</kwd><kwd>удар молнии</kwd><kwd>зона защиты</kwd><kwd>доля ударов</kwd><kwd>ВЛ</kwd><kwd>обратное перекрытие</kwd></kwd-group><kwd-group xml:lang="en"><kwd>lightning protection</kwd><kwd>lightning strike</kwd><kwd>area protection</kwd><kwd>the share of strike</kwd><kwd>power lines</kwd><kwd>reverses overlap</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Базелян Э.М. Проблемы нормирования молниезащиты в России // V Международная конференция по молниезащите. СПб, 2016.</mixed-citation><mixed-citation xml:lang="en">Bazelyan, E. M. problems of standardization of lightning protection in Russia // the V international conference on lightning protection. SPb.: 2016.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ Р МЭК 62305-1-2010. Менеджмент риска. Защита от молнии. Часть 1. Общие принципы. Введ. 2011-12-01. М.: Стандартинформ. 2011.</mixed-citation><mixed-citation xml:lang="en">GOST R IEC 62305-1-2010 "Management of risk. Lightning protection. General principles" dated November 30, 2010 No. 795-St // STANDARTINFORM. 2010.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Гумерова Н.И., Ефимов Б.В., Репкина О.Д. Рекомендации по защите оборудования подстанций от набегающих волн грозового присхождения с использованием ОПН // IV Международная конференция по молниезащите. СПб, 2014. С. 87-97.</mixed-citation><mixed-citation xml:lang="en">Gumerova N. I. Efimov B. V., Repkina O. D. Recommendations on the protection equipment of substations from oncoming waves of storm origin using surge aresters //  IV international conference on lightning protection. SPb.: 2014. P. 87‒97.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Золотых А.Г., Енькин Е.Ю., Подпоркин Г.В., Сиваев А.Д. Применение полимерных изоляторов-разрядников для молниезащиты воздушных линий электропередачи и повышения надежности работы оборудования подстанций 35 и 110 кВ // IV Международная конференция по молниезащите. СПб, 2014. С. 330-334..</mixed-citation><mixed-citation xml:lang="en">Golden A. G., Anikin E. J., Podporkin G. V., Sivaev A. D. the Use of polymeric insulators-arresters for lightning protection of overhead power lines and improve  reliability of substation equipment 35 kV and 110 kV // IV international conference  on lightning protection. SPb.: 2014. Pp. 330‒334..</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Подпоркин Г.В., Енькин Е.Ю., Пильщиков В.Е. Молниезащита ВЛ на основе мультикамерных разрядников нового поколения // IV Международная конференция по молниезащите. СПб, 2014.</mixed-citation><mixed-citation xml:lang="en">Podporkin G. V., Anikin E. Y., sawyers V. E. Lightning protection overhead power lines based on multi-chamber arresters new generation // IV international conference  on lightning protection. SPb: 2014.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">ПУЭ Правила устройства электроустановок. Изд. 7-е. Разд. 2. Введ. 2003-01-01. Утв. Минэнерго России. М.: Изд.НЦ ЭНАС, 2002.</mixed-citation><mixed-citation xml:lang="en">Regulations for Electrical Installation. 7th Edition.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">РД 153-34.3-35.125-99. Руководство по защите электрических сетей 6-1150 кв от грозовых и внутренних перенапряжений. Утв. РАО «ЕЭС России» 12.07.1999. М.: Издательство ПЭИПК, 1999.</mixed-citation><mixed-citation xml:lang="en">GD 153-34.3-35.125-99 "Guide for the protection of electrical networks 6-1150 kV against lightning and internal overvoltages", dated July 12, 1999 Publisher PEIPK. 1999</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">СО 153-34.21.122-2003. Инструкция по устройству молниезащиты зданий, сооружений и промышленных коммуникаций. Утв. Минэнерго России 30.06.2003. ЦПТИ ОРГРЭС, 2004.</mixed-citation><mixed-citation xml:lang="en">SO 153-34.21.122-2003. "Instructions for installation of lightning protection of buildings, constructions and industrial communications", dated 30 June 2003 No. 280  // tisc ORGRES. 2004</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Туманов О.В., Репкина М.Б. Совершенствование систем заземления опор ВЛ с целью повышения грозоупорности ВЛ и ПС // IV Международная конференция по молниезащите. СПб, 2014. С. 155-163.</mixed-citation><mixed-citation xml:lang="en">Tumanov, O. V., Repkina M. B. Improvement of grounding of supports of overhead lines to increase grotophorst PL and substation // IV international conference on  lightning protection. SPb: 2014. P. 155‒163.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Усачев А.Е., Юдицкий Д.М. Методика расчёта грозоупорности воздушных линий электропередачи по параметрам опор и пролётов с учётом ветровой нагрузки // Известия высших учебных заведений. Проблемы энергетики. 2014. № 78. С. 70-76.</mixed-citation><mixed-citation xml:lang="en">Usachev A. E., D. M. Yuditskii Method of calculating grotophorst of overhead power lines in the parameters of the supports and spans taking into account wind loads // proceedings of higher educational establishments: Problems of energy. 2014.  № 7‒8. P. 70‒76.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Усачев А.Е., Юдицкий Д.М. Новая концепция защиты подстанций от волн грозовых перенапряжений // Известия высших учебных заведений: Проблемы энергетики. 2014. № 11-12. С. 94-100.</mixed-citation><mixed-citation xml:lang="en">Usachev A. E., D. M. Yuditskii, a New concept for the protection of substations from lightning surges waves // proceedings of higher educational establishments:  Problems of energy. 2014. № 11‒12. P. 94‒100.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Rizk F.A.M. and F. Vidal, IEEE Trans. Power Deliv., 23(1), 296, 2008.</mixed-citation><mixed-citation xml:lang="en">Rizk, F.A.M. and F. Vidal, IEEE Trans. Power Deliv., 23 (1), 296, 2008.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Cooray V., Nucci C.A., Rachidi F. On the Possible Variation of the Lightning Striking Distance as Defined in the IEC Lightning Protection Standard as a Function of Structure Height. Intern. Conf. on Lightning Protection, Vienna, Austria. 2012.</mixed-citation><mixed-citation xml:lang="en">V. Cooray, C. A. Nucci, F. Rachidi. On the Possible Variation of the Lightning Striking Distance as Defined in the IEC Lightning Protection Standard as a Function  of Structure Height. Intern. Conf. on Lightning Protection, Vienna, Austria, 2012.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
