Detection of inter turn fault in transformer windings by parameters of their transition processes

https://doi.org/10.30724/1998-9903-2019-21-3-14-23

Abstract

The proposed method of detection the inter turn fault of transformer windings relates to the area of defectoscopy and allows detecting inter turn faults in a wide range of damaged (closed) turns. Power and instrument transformers with iron-core are widely used in power networks. As the insulation ages or is damaged, the wires between various transformer sections short circuits occur, which inevitably leads to a complete damage of the transformer. Short- circuited part of the transformer forms an additional winding, the outputs of which are short- circuited. The transition process of current increasing when DC voltage is connected to the transformer outputs occurs in diverse ways in undamaged (cut-off) winding section and in the damaged (short-circuited) section. The current growth rate in the undamaged section of the winding is determined by high magnetization inductance. The inductance of the short-circuited part of the winding is much less, so, the current growth rate in the short-circuited part is significantly greater than the current growth rate in the undamaged part of the winding. The article presents observations from computer models and real measurements of the substation auxiliary power transformer, which show the possibility of determining the presence of a turn fault in regards to the transition process parameters, the rate of current increase and decay in the transformer winding. The device aimed to find the inter turn faults in the transformer windings, working according to the proposed method will be quite simple and have a high sensitivity.

About the Author

R. G. Mustafin
Kazan State Power Engineering University
Russian Federation

Ramil G. Mustafin– candidate of physical and mathematical sciences, the associate professor at "Relay protection and automation of electrical power systems"

Kazan



References

1. Bartley W. Analysis of Transformer Failures. International Association of Engineering Insurers 36 th Annual Conference. Stockholm, Sweden, 2003.

2. Pyatkov AV. Determination of inter turn fault in the windings of a power transformer with switching without excitation. In the collection: Еnergetics - to the agro-industrial complex of Russia. South-Ural State Agrarian University. 2017. pp. 156–160.

3. Oliveira L. Comparing Power Transformer Turn- to-Turn Faults Protection Methods: Negative Sequence Component Versus Space Vector Algorithms. Oliveira L, Cardoso AJM. IEEE Transactions on Industry Applications. 2017. Vol.53: 2817–2825.

4. Tytko O. Definition of turn-fault of stator winding induction motor on the basis of the compensation magnetic field. O Tytko, AV Khudiakov. Технiчна електродинамiка. 2017. № 1. С. 58–61.

5. Fedotov GI. Turn fault of a power transformer and methods for diagnosing them. Fedotov G.I., Golgovskikh AV. Society, science, innovations (NPK-2016) Collection of articles 2nd ed, revised and updated. Vyatka State University. 2016. pp. 2080–2083.

6. Sheryazov SK. Monitoring Device for Power Transformers 6-10. 0.4 kV. Sheryazov S.K., Pyatkov A.V. Proceedings of the LV Intern. Scientific. -Tech. conf. "Achievements of science - agro-industrial production." Chelyabinsk: SUSU. 2016. P. 240–244.

7. Ivanova ZG. Development of a device for detecting inter turn fault in the windings of dry power transformers. Ivanova ZG, Makarova NL. Vestnik Moskovskogo gosudarstvennogo agroinzhenernogo universiteta im. V.P. Goryachkina. VP. 2013. № 1 (57). P. 30–31.

8. Makarova NL. Diagnosing the state of isolation of power transformers of rural electric networks. Makarova NL, Akhmetshin RS. monograph. M .: FGBOU VPO MSAU, 2012.pp 90 .

9. Stanley HH. Power System Relaying. Third Edition. Stanley H. Horowitz, Arun G. Phadke. doi:10.1002/9780470758786. 2008 Research Studies

10. Mustafin RG. Utility model “Device for detecting windings short circuits of transformer windings Patent. RF 07.11.2017 Bull. N 20 Accessed: 02.02.2017.


Review

For citations:


Mustafin R.G. Detection of inter turn fault in transformer windings by parameters of their transition processes. Power engineering: research, equipment, technology. 2019;21(3):14-23. https://doi.org/10.30724/1998-9903-2019-21-3-14-23

Views: 819


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-9903 (Print)
ISSN 2658-5456 (Online)