Using contactless methods of diagnostics of high electric fields

https://doi.org/10.30724/1998-9903-2019-21-4-123-133

Abstract

In the electric power industry of Russia and abroad, special attention is paid to the problem of an increase in the number of accidents caused by damage to high-voltage insulators in high-voltage equipment. An analysis of emergencies at substations and open switchgears [1- 2, 4] was carried out, which showed that in most cases the causes of damage to high-voltage insulators are natural aging in an applied electric field, overvoltage, and the presence of initial defects in the manufacture of high-voltage insulators. Based on this fact, we developed various methods of non-contact diagnostics of high-voltage insulators in order to identify defects at an early stage of their development. Particular attention was paid to the method of partial discharges because the characteristics of partial discharges provide information on the parameters of defects. The article describes a set of non-contact methods for remote diagnostics of high-voltage insulators; a two-channel method for remote diagnostics of the operating state of high-voltage insulators, based on the registration of partial discharges by electromagnetic and acoustic sensors; a device that allows visual inspection and the search for faulty high-voltage equipment; remote non-contact method for recording electric fields of high tension of industrial frequency, as well as their spatial orientation based on the electro-optical effect. We developed a mock-up of a portable diagnostic device for implementing research methods for high-voltage dielectric elements to diagnose their technical condition using the described complex of non-contact methods. The measuring device as part of a portable diagnostic device consists of a set of sensors for collecting diagnostic information detected by electromagnetic, acoustic and electro-optical sensors and a voltage phase signal applied to the studied highvoltage insulator. The simultaneous use of several sensors at once made it possible to increase the accuracy of localization of partial discharges in high-voltage insulators. Visualization of diagnostic results is possible at the control room in the form of amplitude-phase, frequencyphase and amplitude-frequency diagrams of the distribution of characteristics of partial discharges and on a portable device in the form of radiation intensity from the selected sensor. A portable diagnostic device made it possible in laboratory conditions to study electrophysical processes in various dielectric materials and products under the influence of strong alternating electric fields. A study was made of the features of defects on the rod and the terminal-terminal contact, a diagram of the electrophysical processes accompanying the emission of partial discharges was constructed, and the causes of their occurrence were established.

About the Authors

A. V. Golenischev-Kutuzov
Kazan State Power Engineering University
Russian Federation
Alexandr V. Golenishchev-Kutuzov

Kazan



D. A. Ivanov
Kazan State Power Engineering University
Russian Federation
Dmtriy A. Ivanov

Kazan



A. A. Potapov
Kazan State Power Engineering University
Russian Federation
Andrey A. Potapov

Kazan



V. I. Krotov
Kazan State Power Engineering University
Russian Federation
Vladimir I. Krotov

Kazan



References

1. Yi Hu, Kai Liu Inspection and Monitoring Technologies of Transmission Lines with Remote Sensing Academic Press. 2017; 281-508. Available at: https://doi.org/10.1016/B978-0-12-812644-8.00005-9.

2. Bartnikas R. Partial discharges. Their mechanism, detection and measurement. IEEE Transactions on Dielectrics and Electrical Insulation. 2018; 9(5):763-808. doi: 10.1109/TDEI.2002.1038663.

3. Slavinsky AZ., Ustinov V.N. Review in "Materials and development of new test methods and diagnostic tools» Unified Energy Network. 2016;4:6-11.

4. Rodrigo Mor, L.C. Castro Heredia, D.A. Harmsen, F.A. Muñoz, A new design of a test platform for testing multiple partial discharge sources. International Journal of Electrical Power & Energy Systems, 2018;94:374-384.

5. Simanovski IV. Polymer insulator breakdown Indicator Electrical Equipment. 2013;6:21-24

6. Hohlov AV., Vorkunov OV., Afanasyeva TI. Analysis of modern methods and tools for the diagnosis of overhead transmission line insulator. Bulletin of modern research. 2018; 20(5-3):545-547.

7. Gimadiev RA., Ivshin IV., Muhortov IS., Bilalov FF., Valiullin RR., Miftahova N. The effectiveness of methodology for assessing the results of the medium-voltage cable lines technical state monitoring. Energy Tatarstan. 2016; 2: 68-71.

8. Runde D., Brunken S., Ruter C., Kip D. Integrated optical electric field sensor based on a Bragg grating in lithium niobate Appled Physics.2007;86 (1):91-95.

9. Vorotnitsky VE., Dmitriev IN., Mlotok AV., Demin AN. Diagnostics of mechanical condition of the locomotive-Rod high voltage isolation porcelain disconnectors in operation .Unified Energy Network. 2014;2:2-14.

10. Svistunov NA. Analysis of diagnostics methods of technical condition of electrotechnical devices, based on detection and measurement of the level of partial discharges. Izvestiya TulGU Technical science. 2018;12:100-102.

11. Ivanov DA., Golenishchev-Kutuzov AV., Yaroslavsky DA., Sadykov MF. Portable complex for remote control of high-voltage insulators using wireless data collection and transmission module . ARPN Journal of Engineering and Applied Sciences. 2018;13(6):2358-2362.

12. Yaroslavsky DA., Konov MF., Ivanov AB., Goryachev DA. Methodology of ice coating monitoring on overhead transmission lines considering misalignment using wireless communication channel sensors. ARPN Journal of Engineering and Applied Sciences. 2017;12(22): 6479-6482.

13. Balaban RN., Zaripov DK., Nasibullin RA., Margulies SM. Optical indication of the defect of high voltage insulation design. Power engineering: research, equipment, technology. 2017; 3-4:119-125.

14. Stepanov VM., Sudavnyj AS. Defects in the insulation of electrical devices, leading to the appearance of partial discharges. Proceedings of Tula State University. Technical science. 2018;6:386-391.

15. Golenishchev-Kutuzov AV., Golenishchev-Kutuzov VA., Kalimullin RI., Mardanov GD., Potapov AA. Ultrasonic tunable transducer on domain structures. Ferroelectrics. 2012; 441(1):25-29.


Review

For citations:


Golenischev-Kutuzov A.V., Ivanov D.A., Potapov A.A., Krotov V.I. Using contactless methods of diagnostics of high electric fields. Power engineering: research, equipment, technology. 2019;21(4):123-133. (In Russ.) https://doi.org/10.30724/1998-9903-2019-21-4-123-133

Views: 512


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-9903 (Print)
ISSN 2658-5456 (Online)