The study of health and quality of operation of the transformer equipment electrical systems

https://doi.org/10.30724/1998-9903-2020-22-3-23-35

Abstract

Detection of defects at an early stage of their occurrence, especially for power transformers that have worked out the standard term, is an acute problem. This article discusses the possibility of using the system of monitoring, control and diagnosis of transformer equipment (SMUID) electrical systems in conjunction with the automated control system of electrical equipment (ASU ETO) and automated information-measuring system of commercial electricity metering (AIIS KUE) with the use of QR-code, as well as using TeamViewer for the operational elimination of accidents and identify abnormal operation of transformer equipment. Transformer monitoring system is designed for monitoring isolation, recording and analysis of partial discharges, monitoring of technical condition ensuring maximum fault-free service life of transformers. In addition, the introduction of automated diagnostics and electrical equipment is a necessary condition for the introduction of SmartGrid technology in industrial electric networks, contributes to the reduction of capital investments in the renewal of the equipment fleet. The methods currently used do not detect dangerous insulation degradation, are not sensitive to its aging, and in some cases mistakenly assess the isolation condition. The work analyses the operability and quality of the systems under consideration, shows the hierarchical structure of SMUID. By applying the proposed idea with the QR-code, it is possible to speed up the process of searching for information about the current technical state of electrical equipment.

About the Authors

A. R. Denisova
Kazan State Power of Engineering University
Russian Federation
Alina R. Denisova


D. P. Spasov
Kazan State Power of Engineering University
Russian Federation
Denis P. Spasov


A. R. Galyautdinova
Kazan State Power of Engineering University
Russian Federation
Alsu R. Galyautdinova


V. R. Ivanova
Kazan State Power of Engineering University
Russian Federation
Vilija R. Ivanova


References

1. Fetisov LV, Rozhenzova NV, Bulatov OA. Improvement of the quality of electric energy in low voltage networks. Izv. Higher educational institutions. Problet.us anticus. 2018;11-12:99-106.

2. Ivanova VR, Fetisov LV. Development of a training stand for the efficient and safe operation of backup power supply at industrial enterprises. Izv. universities. Energy problems. 2018;9-10:165-169.

3. Chichov SI. Monitoring i diagnostika oborudovannykh setey regional'noy setevoy kompanii "Tambovenergo". Povysheniye effektivnosti sredstv obrabotki informatsii na baze matematicheskogo modelirovaniya: Mater, dokl. 9 Vseross. nauch.-tekhn. konf. 27-28 aprelya 2009 g. Tambov, 2009. S. 461-472.

4. Vinogradova LV, Ignat'yev KB, Klimov DA, et al. Diagnostika maslonapolnennogo elektrooborudovaniya na osnove ekspertnykh system. Integratsiya nauki i proizvodstva. Mater, konf. TRAVEK. M .: VEI, 2004. 180s. 5. Rybakov LM, Ancharova TV, Akhmetshii RS. Diagnostirovaniye silovykht ransformatorov 1 i 2 gabaritov napryazhennosti 10 / 0,4kVpod rabochim napryazheniyem s ispol'zovaniyem chastotnykh kharakteristik. Vestnik MEI. 2005;5:39-48.

5. Chichov SI, Kalinin VF, Glinkin YeI. Informatsionno-izmeritel'naya sistema tsentral'nogo upravleniya stolovymi setyami. M .: Mashinostroyeniye, 2009. 176 s.

6. Rozhentsova NV, Bashirov MG, Khal'fiyeva AM, et al. Problemy obespecheniya nadezhnosti raspredelitel'nykh setey promyshlennykh predpriyatiy. I. vuzov. Problemy energetiki. 2010;3-4:85-93.

7. Ivanova VR, Ivanov AS, Fetisov LV. The development of an automated station for group soldering of the led lines. 2018 14th International scientific-technical conference on actual problems of electronic instrument engineering (APEIE) 44894 proceedings. pp. 336 -338.

8. Bogomolov VS, Kasatkina TE, Bushes SS. Analysis of the causes of damage and the results of the inspection of the technical condition of transformer equipment. Vestnik VNIIE, 2014.

9. Sim Power Systems For Use with Simulink. User’s Guide. The MathWorks Inc., 2014. P.411.

10. Vanin BV, et al. Damage to power transformers of 110–500 kV in operation. Moscow: VNIIEMEI JSC (TU) RAO UES of Russia.

11. Lopukhov I. Ensuring safety of LFS for process control systems. Modern automation technologies. M., 2014;2:6.

12. Kominek D, Byres. Effective OPC Security for Control Systems. Solutions you can bank on. Доступно по :http://www.tofinosecurity.com/effective-POC-solutions.

13. Trace Mode IDE 6.09 Base :Справка. M. : AdAstra Research Group, Ltd., 2014.

14. Denisova АR, Spasov DP, Galyautdinova AR. Use of a QR code for industrial purposes. Electrical Equipment: Operation and Repair. 2019;5:41.

15. Rozhentsova NV, Larionov SN, Khal'fiyeva AM. Ispol'zovaniye neyrosetevykh algoritmov dlya povysheniya nadezhnosti raboty sovremennykh energosberegayushchikh sistem. Trudynauchno-prakt. sem. «Energosberezheniye na predpriyatiyakh promyshlennosti i zhilishchno-kommunal'nogokhozyaystva». Ufa: Gilem. S. 61-64.

16. Rudakov AI, Nursubin MS, Rozhentsova NV, et al. Povysheniye energoeffektivnosti stupeney konfuzornogo ezhektora s pul'siruyushchim dvizheniyem aktivnogo potoka v sostave zhidkostno-kol'tsevogo vakuum-nasosa. Vestnik Kazanskogo tekhnologicheskogo universiteta:. M-voobraz. I nauki Rossii, Kazan. nats. issled. tekhnol. un-t. Kazan': KNITU, 2104;17(17):150-158.

17. Vasenin AB. Osobennosti primeneniya metodov monitoring elektrooborudovaniya energeticheskikh ob"yektov. Avtomatizatsiya i IT v energetike. №8 M.: Izdatel'skiy dom «ID AVIT-TEK», 2018. pp. 12-19.

18. BadunJ, VitolinaS, MaskalonokV. Methods of predicting the remaining life of power transformers and their components. Energy and electrical engineering. 2013;31:123-126.

19. Karandaev AS, Khramshin VR, Khramshin RR, et al. Conceptual Area of Development of Power Saving Thyristor Electric Drives of Rolling Mills. 2016.

20. Karandaev AS, Evdokimov SA, Sarlybaev AA, et al. Requirements of a system for monitoring the technical condition of the transformer of a high-power arc steelmaking furnace. Mashinostr.: SetevoiElektr. Nauch. Zh. 2014;2:655-663.

21. Karandaev AS, Evdokimov SA, Khramshin VR, et al. Diagnostic functions of a system for continuous monitoring of the technical condition of the transformers of arc steelmaking furnaces. Metallurgist. 2014;58(7-8):655-663.

22. Bernat P, Hytka Z, Kacor P. Indication of failures of rotor bar on induction machine with squirrel cage rotor in its external electromagnetic field. In: Proceedings of the 16th International Scientific Conference on Electric Power Engineering (EPE). 2015, pp. 691-696.

23. Kurilin SP, Denisov VN. Metody I prilozheniya matematicheskogo modelirovaniya v elektrotechnike Monograph. Smolensk, Smolenskiy Filial RUK Publ, 2014, 242 p.

24. Ameid T, Menacer A, Talhaoui H, et al. Broken rotor bar fault diagnosis using fast Fourier transform applied to field-oriented control induction machine: simulation and experimental study. International Journal of Advanced Manufacturing Technology. 2017;92(1-4):917-928. doi: 10.1007/s00170-017-0143-2.


Review

For citations:


Denisova A.R., Spasov D.P., Galyautdinova A.R., Ivanova V.R. The study of health and quality of operation of the transformer equipment electrical systems. Power engineering: research, equipment, technology. 2020;22(3):23-35. (In Russ.) https://doi.org/10.30724/1998-9903-2020-22-3-23-35

Views: 528


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-9903 (Print)
ISSN 2658-5456 (Online)