Power factor correction in power delivery systems with mutipulse nonlinear loads

https://doi.org/10.30724/1998-9903-2020-22-6-3-15

Abstract

THE PURPOSE. Мutipulse rectifiers are widely used as a nonlinear loads in industrial distribution systems. The advantage of mutipulse rectifiers is low harmonic emission and high power factor. However input currents of mutipulse rectifiers have a wide spectrum including characteristic and noncharacteristic harmonics. This has a negative impact on the power quality. Shunt capacitors are the simplest form of reactive power compensation in industrial power distribution systems. However power systems with nonlinear loads suffer from severe harmonic distortion due to the parallel resonance between capacitors and system inductance. Special compensating devices for reactive power compensation and correction of power system frequency response for resonances damping are necessary. METHODS. In this paper shunt compensating devices for power delivery systems with multipulse nonlinear loads are considered. Proposed devices are composed of 3-5 order parallel connected passive broadband filters. They provide power factor correction, voltage and current harmonics mitigation and resonance modes damping. A general broadband filter design procedure based on frequency and reactive power scaling of normalized filter parameters is developed. RESULTS. Characteristics of different compensating devices configurations using broadband passive filters are discussed. It is shown that broadband filtering devices enable compensation of fundamental frequency reactive power as well as mitigation of voltage harmonic level to values determined by Russian and international standards. Proposed devices have lower fundamental power losses in c omparing with known solutions. CONCLUSION. Proposed analytical design method is applicable to broadband filters of different orders.

About the Authors

D. E. Egorov
Siberian Federal University
Russian Federation

Denis E. Egorov

Krasnoyarsk



V. P. Dovgun
Siberian Federal University
Russian Federation

Valery P. Dovgun

Krasnoyarsk



N. P. Boyarskaya
Кrasnoyarsk State Agricultural University
Russian Federation

Nataliya P. Boyarskaya

Krasnoyarsk



A. V. Jan
Siberian Federal University
Russian Federation

Anastasiya V. Yan

Krasnoyarsk



A. S. Slyusarev
Siberian Federal University
Russian Federation

Aleksandr S. Slusarev

Krasnoyarsk



References

1. Zhezhelenko IV. Vysshie garmoniki v sistemakh promyshlennogo elektrosnabzheniya prompredpriyatii. Moscow: Energoatomizdat Publ., 2000, 331 p.

2. Kovernikova LI, Tulckiy VN, Shamonov RG. Katchestvo elektreoenergii v EES Rosii, tekustchie problem I neobkhodimye resheniya. Elektroenergiya. Peredatcha I raspredelenie. 2016;2 (35):28-38.

3. Rodríguez J, Pontt J, Silva C, et al. Large Current Rectifiers: State of the Art and Future Trends. IEEE trans. on Industrial Electronics. 2005;52(3):738-745.

4. Singh B,Gairola S, Singh BN, et al. Multipulse AC–DC Converters for Improving Power Quality: A Review. IEEE trans. on Power Electronics. 2008;23(1):260-281.

5. Zhiheng M., Zheng X., Yujun L. Harmonic Analysis and Simulation of Multi-pulse Rectifiers Applied in Electrolysis Industry. 2014 IEEE Industry application society annual meeting, 2014, pp. 1 -5, doi: 10.1109/IAS.2014.6978498.

6. Badrzadeh D., Smith K., Wilson R. Designing passive harmonic filters for an aluminum smelting plant. IEEE trans. on Industry Applications. 2011;47(2):973-983.

7. Li X, Xu W, Ding T. Damped high passive filter – a new filtering scheme for multipulse rectifier systems. IEEE trans. on Power Delivery. 2017;32(1):117-124.

8. Wang Y, Xu W. A Shared Resonance Damping Scheme for Multiple Switchable Capacitors. IEEE trans. on Power Delivery. 2018;33(4):1973-1980.

9. Wang Y, Xu S, Xu W, Wu J., Xiao X. Comparative Studies on Design Methods for Detuned CType Filter. IEEE trans. on Power Delivery. 2020;35(4):1725-1734.

10. Xu W, Ding T, Li X, Liang H. Resonance-Free Shunt Capacitors – Configurations, Design Methods and Comparative Analysis. IEEE trans. on Power Delivery. 2016;31(5):2287-2295.

11. Li X, Wang Y, Xu W. A new filtering scheme for HVDC terminals based on damped high -pass filter. IEEE trans. on Power Delivery. 2019;34(5):2050-2057.

12. Ding T, Xu W, Liang H. Design method for third-order High-pass filter. IEEE trans. on Power Delivery. 2016;31(1):402-403.

13. Dovgun VP, Boyarskaya NP, Egorov D.E., et al. Sintez shirokopolosnykh filtrov garmonik. Izvestiya vuzov. Problemy energetiki. 2014;5-6:85-91.

14. Das J. Design and Application of a Second-Order High-Pass Damped Filter for 8000-hp ID Fan Drives A Case Study. IEEE trans. on Industry Applications. 2015;51(2):1417-1426.

15. Dovgun VP, Egorov DE, Novikov VV, et al. Parametritcheskii sintez shirokopklosnyh filtrov Elektritchestvo. 2018;12:14-21.

16. Dovgun VP, Egorov DE, Prozorov NR, et al. Broadband Power Filters for Power Supply Systems with Multiphase Converters. Russian Electrical Engineering. 2020;91(5):330-334.


Review

For citations:


Egorov D.E., Dovgun V.P., Boyarskaya N.P., Jan A.V., Slyusarev A.S. Power factor correction in power delivery systems with mutipulse nonlinear loads. Power engineering: research, equipment, technology. 2020;22(6):3-15. (In Russ.) https://doi.org/10.30724/1998-9903-2020-22-6-3-15

Views: 379


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-9903 (Print)
ISSN 2658-5456 (Online)