Ways to increase the maneuverability characteristics of the CCGT when operating in load control modes (for example, CCGT-450)
https://doi.org/10.30724/1998-9903-2023-25-1-58-73
Abstract
THE PURPOSE The article is devoted to the analysis of the problems that arise during the operation of heating CCGTs of the type CCGT-450 at reduced loads with their participation in the regulation of electrical and thermal loads. The description of the main limitations of the adjustment range of gas turbines, and the maneuverability characteristics of the CCGT, an analysis of some existing technical proposals for expanding the adjustment range is given. It is shown that the application of these proposals, expanding the boundaries of the adjustment range in small quantities, does not solve the problem as a whole. The description and research results of the proposed new technical solutions to expand the adjustment range and maneuverability characteristics of the CCGT - 450 are given.
METHODS. When solving the tasks, the analysis, comparison and generalization of energy characteristics, modeling of modes were carried out.
RESULTS. It is shown that: the use of methods for converting part of the central heating system and the central heating system as a whole of the T-125/150 steam turbine into a low-steam mode together with bypass steam distribution will expand the adjustment range to a level comparable to the adjustment range of condensing power units on gas-fuel oil;. when shutting down the CCGT-450 operating in condensation mode and when operating it in the GTU-CHP mode during periods of night failure of the electrical load, the conversion of the steam turbine to motor mode significantly improves the maneuverability and reliability characteristics of the steam turbine and the CCGT as a whole. conclusion. The use of methods for transferring part of the central heating system and central heating system as a whole and bypass steam distribution expand the adjustment range of the CCGT-450, respectively, by 7.8, 10.1 and 16.0% of the rated power; When the CCGT-450 is operating in condensation mode when the CCGT is stopped and when it is operating in the GTU-CHP mode during periods of night failure of the electric load, the steam turbine is transferred the MR significantly improves the maneuverability and reliability characteristics of the steam turbine by reducing the duration of start-up and loading of the steam turbine by 40 and 14.5 minutes, respectively, reducing starting fuel losses, eliminating temperature fluctuations of steam and metal of the steam intake organs of the central pump and the control stage during start-up;
About the Author
E. K. ArakelyanRussian Federation
Edik K. Arakelyan
Moscow
References
1. Davydov NI, Zorchenko NV, Davydov AV, et al. Model studies of the possibility of participation of PSU in the regulation of the frequency and flow of power in the UES of Russia. Heat Power. 2009.
2. Radin YA. Research and improvement of maneuverability of steam-gas installations. Autoabstract on the sofa. Uch. Art. Doc. Techn. Sciences. Moscow, 2013, 42c.
3. Radin YuA, Davydov AV, Chugin AV. Determination of the permissible control range of the load of the GGP 450T power unit when operating in condensation mode. Heat and power engineering. 2004;5:47-52.
4. Davydov AV. Study of variable modes of binary PSU to increase maneuverability. Dis. ... Kand. techn. Sciences. M.:,2009. 20s.
5. Arturo Losi, Giovanni Mtrcurio Casolino, Mario Russo. Design choices for combined cycle units and profit-based unit commitment November 2012. International Journal of Electrical Power & Energy Systems 42(1)p:693-700.
6. Arakelyan EK, Bolonov VO, Sakharov KV. Selection of optimal modes of operation of binary PSU at reduced loads. New in the Russian electric power industry. 2011. 11.
7. Technical requirements for generating equipment of participants of the wholesale market. JSC «System Operator of the Unified Power System». M.:2021, 184p.
8. Arakelyan EK, Ilyin ET, Rogalev ND. Modes of work and operation of TES. Textbook/ M.: Publishing House of IEI. 2021. 520p.
9. Arakelyan EK. Optimal management of the modes of PSU and GTU. Training manual. M.: MEI Publishing House, 2020. 56 p.
10. Baxter A, Sauford M, Smith R, et al. Analyses of Combinet Cycle Operating Patterus. Probilistic Metods Applied to Power Systems . October,2004.
11. Tsanev SV, Burov VD, Goncharenko DV, et al. Determination of the lower load limit of steam-gas heating unit PGU-450T. Energy saving and water treatment. 2008;6:31-35.
12. Shoenaev AS. Development and Research of Analytical Model of PSU 450: Dis. ... Kand. of Sciences. M.: NY MEI, 2011.
13. Patent. C12144619 Russian Federation, MPC 7F01 K13/00. Steam gas plant/, P.A.Berezinets, G.G.Olkhovsky; JSC «VTI». - 98108140/06; declared.24.04.1998; Corrigendum.20.01.2000, Bul. 2.
14. Tverskaya YuS, Muravyov IK. Improvement of the air flow control system in the compressor of gas turbine units of PSU units taking into account the changing mode and external climatic factors. Automation in industry. 2016;8:61-64.
15. Korshikova AA. Selection of optimal parameters, schemes and operating modes of the double-block GGP with the aim of maximal expansion of the control range (for GGG-450T. Disses. Technical Sciences. M.:2014. 20p.
16. Arakelyan EK, Korshikova AA, Khurshudyan SR. Effective application of additional low pressure combustion chamber to improve the mode of the PGU-450 power unit at reduced loads. Bulletin MPE. 2013. P.3.
17. Sakharov VK. Selection of optimal mode of power units PSU with the participation of them in the regulation of the power system. Dis. channel. techn. Sciences. M.:, 2013. -20s.
18. Arakelyan EK, Sakharov KV. Study of the temperature state of the stages of the KVD steam turbine T-125/150 PSU-450 when working in a low-steam mode. New in the Russian power industry. 2013. P.1.
19. Arakelyan EK, Khurshudyan SR. Choice of optimal modes of gas turbines PGU-450T under reduced loads. New in the Russian electric power industry. 2013. P.7.
20. Hurshudian SR. Optimization of PGU modes with its participation in the regulation of power and frequency in the power system (on the example of PGU-450). Dis. kand.techn.. M.:2014. 20p.
21. Arakelyan EK, Andriushin KA, Bezelgin IY. Study of the temperature state of the flow part of the steam turbine T-125/150 when it operates in the unmanned and motor modes. Electrical stations. 2015;6:21-26.
22. Arakelyan EK., Pikina GA, Andryushin AV. Features of turbine operation in low-flow hydroin the turbing, PashchenkoF.F. Modelstages.
Review
For citations:
Arakelyan E.K. Ways to increase the maneuverability characteristics of the CCGT when operating in load control modes (for example, CCGT-450). Power engineering: research, equipment, technology. 2023;25(1):58-73. (In Russ.) https://doi.org/10.30724/1998-9903-2023-25-1-58-73