Preview

Power engineering: research, equipment, technology

Advanced search

Comprehensive assessment of factors affecting the operational reliability of low-voltage asynchronous electric motors of a coal mining complex

https://doi.org/10.30724/1998-9903-2024-26-5-3-18

Abstract

THE RELEVANCE of this study lies in solving the problem of reliable functioning of elements of energy systems and ensuring their effective operation during open-pit mining. The paper presents a methodological approach that allows us to assess the level of reliability of low-voltage asynchronous electric motors in a coal mine with complex mining, geological and climatic conditions of production. THE PURPOSE of the work is to quantify the operational factors affecting the service life of an asynchronous electric motor with a short-circuited rotor. Attention is focused on how influencing factors, different in physical basis, among which electrical parameters are highlighted – the coefficient of voltage asymmetry in the reverse sequence, the coefficients of harmonic voltage components and environmental parameters – temperature, air humidity and dustiness, affect the dynamics of changes in the service life of an asynchronous electric motor. Asynchronous electric motors used at one of the enterprises of JSC SUEK in the Trans-Baikal Territory are considered as an object of research. METHODS. The main tool for the implementation of research tasks is computer modeling based on the Matlab software package. RESULTS. The studies were performed on an asynchronous electric motor with a short-circuited rotor with Ph = 3 kW, rated speed 1500 rpm. The simulation of the operating mode of the electric motor under study was performed by changing the experimental parameters: the values of the total coefficient of harmonic voltage components (KU) – from 4 to 12% with a range of 2%; the values of the voltage asymmetry coefficient in the reverse sequence (K2U) – from 0 to 4% with a range of 1%; the ambient temperature (∆Tокr) – from -30°C to +30°C with a range of 10°C; air humidity values (Vc) – 20% and 60%; dust thermal conductivity coefficient values (Kт) – 0,12 and 0,28. Based on the obtained research results, diagrams are constructed that clearly illustrate the dynamics of changes in the service life of an asynchronous electric motor depending on the combination of influencing factors. CONCLUSION. The trends in solving the issues of reliable functioning of a coal mining enterprise with the presence of asynchronous electric motors and ensuring their efficient operation are the most priority, mainly focused on maintaining the stability of technological processes and maintaining the production volumes of a coal mining enterprise. The stability of the electric motor to certain influencing factors is estimated and their critical values are established. Recommendations on the use of asynchronous electric motors are formulated, taking into account their operating conditions.

About the Authors

V. V. Romanova
Trans-Baikal State University ; Branch of the National Research University «Moscow Power Engineering Institute»
Russian Federation

Victoria V. Romanova

Chita; Volzhsky



A. G. Batukhtin
Trans-Baikal State University
Russian Federation

Andrey G. Batukhtin

Chita



K. V. Suslov
Trans-Baikal State University ; National Research University «Moscow Power Engineering Institute»
Russian Federation

Konstantin V. Suslov

Chita; Moscow



S. V. Khromov
Trans-Baikal State University
Russian Federation

Sergey V. Khromov

Chita



V. А. Galyatin
Trans-Baikal State University
Russian Federation

Vladislav А. Galyatin

Chita



References

1. Afanasyev VYa. Ugol' Rossii: sostojanie i perspektivy. M.: SIC INFRA-M. 2017; 271 p. (In Russ).

2. Kovernikova LI, Shamonov RG, Sudnova VV. Kachestvo jelektricheskoj jenergii, sovremennoe sostojanie, problemy, predlozhenija po ih resheniju. ed. by N.I. Voropai. Novosibirsk: Nauka. 2017; 219 p. (In Russ).

3. GOST 32144 – 2013. Electrical energy. Electromagnetic compatibility of technical means. Standards of quality of electric energy in general-purpose power supply systems. Moscow: Standartinform. 2014; 19 p. (In Russ).

4. Zapanov OV, Kovernikova LI. On the power quality of electrical energy supplied to joint stock company «Aleksandrovsky mine». E3S Web of Conferences. 2020; 209 (07012): 6. DOI: https://doi.org//10.1051/e3sconf/202020907012.

5. Nazarychev AN. Reliability and assessment of the technical condition of the equipment of power supply systems. 2020; 224 p. (In Russ).

6. Khomutov SO. Analysis of the influence of external influencing factors on the state of insulation of electric motors. Polzunovskiy vestnik. 2005; 4(3): 260 – 267. (In Russ).

7. Sebok M, Gutten M, Kucera M, et al. Condition analysis of electrical machines by thermovision. Przeglad Elektrotechniczny. 2020; 96(8): 47 – 50. DOI: https://doi.org/10.15199/48.2020.08.10.

8. Romanova VV, Suslov KV, Khromov SV. Multi-factor analysis of external effects influencing the operational reliability of asynchronous electric motors. E3S Web of Conferences. 2020; 216 (01084): 4. DOI: https://doi.org/10.1051/e3sconf/202021601084.

9. Mohammed JA-K, Al-Sakini SR, Hussein AA. Assessment of disturbed voltage supply effects on steady-state performance of an induction motor. International Journal of Electrical and Computer Engineering (IJECE). 2020; 10(3): 2259 – 2270. DOI: http://doi.org/10.11591/ijece.v10i3.pp2259-2270.

10. Sorin D, Mihai I, Marilena S, et al. The Induction Machine Operating from a Voltage Supply, Unbalanced and Polluted with Harmonics: A Practical Approach, 15th International Conference on Engineering of Modern Electric Systems (EMES), Oradea, Romania. 2019; 181 – 184.

11. Romanova VV, Suslov KV, Khromov SV, Batukhtin AG. Analysis of the degree of influence of the asymmetry of the supply voltage on the operational reliability of low-voltage asynchronous electric motors. Proceedings of the higher educational institutions. Energy sector problems. 2022; 24(4): 131 – 141. DOI:10.30724/1998-9903-2022-24-4-131-141. (In Russ).

12. Tabora JM, de Matos EO, Soares TM, et al. Voltage unbalance effect on the behavior of IE2, IE3 and IE4 induction motor classes. Proc. on VII Simpósio Brasileiro de Sistemas Elétricos (SBSE). Santo 2020; 6. DOI: https://doi.org/10.1109/ACCESS.2020.3029794.

13. Romanova VV, Suslov KV, Khromov SV. Ensuring the reliability of power supply systems by improving the quality of electrical energy. AIP Conference Proceedings. 2023; 2552 (070017): 7. DOI: https://doi.org/10.1063/5.0117210.

14. Tekhnicheskie kharakteristiki asinkhronnykh elektrodvigatelei serii AIR. Nominal'naya chastota vrashcheniya 1500 ob/min [Electronic resource]. URL: http://www.elektrikii.ru/publ/6-1-0-55. Accessed: 08 June 2024. (In Russ).

15. Kopylov IP. Proektirovanie jelektricheskih mashin. M.: Yurayt Publishing House. 4th ed. 2024; 828 p. (In Russ).

16. Shaitor NM. Calculation and analysis of temperature fields of asynchronous motors. Power plants and technologies. 2021; 7(2): 112 – 118. (In Russ).

17. Shidlovsky AK. Povyshenie kachestva jenergii v jelektricheskih setjah. Kiev: Naukova dumka. 1985; 268 p. (In Russ).

18. Kudinov VA. Tehnicheskaja termodinamika i teploperedacha. M.: Yurayt Publishing House. 4th ed. 2024; 454 p. (In Russ).

19. Sharov NA, Dudayev RR, Krishchuk DI, Liskova MYu. Dust suppression methods in coal mines of the Far North. Perm Journal of Petroleum and Mining Engineering. 2019; 19(2): 184 – 200. DOI: 10.15593/2224-9923/2019.2.8.

20. GOST IEC 60034-2A-2012. Electric rotating machines. Part 2 – Methods for determining losses and efficiency of rotating electric machines during tests (excluding machines for traction vehicles). Measurement of losses by the calorimetric method. Moscow: Standartinform, 2014; 19 p. (In Russ).

21. Krasnoshchekov EA, Sukomel AS. Zadachnik po teploperedache. 4th ed. M.: Energy.1980; 288 p. (In Russ).

22. GOST 30804.4.7 – 2013 (IEC 61000-4-7:2009). Electromagnetic compatibility of technical means. General guidance on measuring instruments and measurements of harmonics and interharmonics for power supply systems and technical means connected to them. Moscow: Standartinform, 2013; 34 p. (In Russ).


Review

For citations:


Romanova V.V., Batukhtin A.G., Suslov K.V., Khromov S.V., Galyatin V.А. Comprehensive assessment of factors affecting the operational reliability of low-voltage asynchronous electric motors of a coal mining complex. Power engineering: research, equipment, technology. 2024;26(5):3-18. (In Russ.) https://doi.org/10.30724/1998-9903-2024-26-5-3-18

Views: 266


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-9903 (Print)
ISSN 2658-5456 (Online)