COMPARATIVE ESTIMATE OF THE PROPORTION OF LIGHTNING STRIKES IN THE TOWERS AND THE UPPER PHASE WIRE IN THE SPAN OF THE OVERHEAD POWER LINES WITHOUT GROUND WIRE
https://doi.org/10.30724/1998-9903-2018-20-3-4-3-10
Abstract
About the Authors
D. M. YuditskyRussian Federation
Research and production company Silesta Ltd
A. E. Usachev
Russian Federation
State Educational Institution "Kazan State Power Engineering
University", chair «Power Stations», Professor, Doctor of Physics and Mathematics
References
1. Bazelyan, E. M. problems of standardization of lightning protection in Russia // the V international conference on lightning protection. SPb.: 2016.
2. GOST R IEC 62305-1-2010 "Management of risk. Lightning protection. General principles" dated November 30, 2010 No. 795-St // STANDARTINFORM. 2010.
3. Gumerova N. I. Efimov B. V., Repkina O. D. Recommendations on the protection equipment of substations from oncoming waves of storm origin using surge aresters // IV international conference on lightning protection. SPb.: 2014. P. 87‒97.
4. Golden A. G., Anikin E. J., Podporkin G. V., Sivaev A. D. the Use of polymeric insulators-arresters for lightning protection of overhead power lines and improve reliability of substation equipment 35 kV and 110 kV // IV international conference on lightning protection. SPb.: 2014. Pp. 330‒334..
5. Podporkin G. V., Anikin E. Y., sawyers V. E. Lightning protection overhead power lines based on multi-chamber arresters new generation // IV international conference on lightning protection. SPb: 2014.
6. Regulations for Electrical Installation. 7th Edition.
7. GD 153-34.3-35.125-99 "Guide for the protection of electrical networks 6-1150 kV against lightning and internal overvoltages", dated July 12, 1999 Publisher PEIPK. 1999
8. SO 153-34.21.122-2003. "Instructions for installation of lightning protection of buildings, constructions and industrial communications", dated 30 June 2003 No. 280 // tisc ORGRES. 2004
9. Tumanov, O. V., Repkina M. B. Improvement of grounding of supports of overhead lines to increase grotophorst PL and substation // IV international conference on lightning protection. SPb: 2014. P. 155‒163.
10. Usachev A. E., D. M. Yuditskii Method of calculating grotophorst of overhead power lines in the parameters of the supports and spans taking into account wind loads // proceedings of higher educational establishments: Problems of energy. 2014. № 7‒8. P. 70‒76.
11. Usachev A. E., D. M. Yuditskii, a New concept for the protection of substations from lightning surges waves // proceedings of higher educational establishments: Problems of energy. 2014. № 11‒12. P. 94‒100.
12. Rizk, F.A.M. and F. Vidal, IEEE Trans. Power Deliv., 23 (1), 296, 2008.
13. V. Cooray, C. A. Nucci, F. Rachidi. On the Possible Variation of the Lightning Striking Distance as Defined in the IEC Lightning Protection Standard as a Function of Structure Height. Intern. Conf. on Lightning Protection, Vienna, Austria, 2012.
Review
For citations:
Yuditsky D.M., Usachev A.E. COMPARATIVE ESTIMATE OF THE PROPORTION OF LIGHTNING STRIKES IN THE TOWERS AND THE UPPER PHASE WIRE IN THE SPAN OF THE OVERHEAD POWER LINES WITHOUT GROUND WIRE. Power engineering: research, equipment, technology. 2018;20(3-4):3-10. (In Russ.) https://doi.org/10.30724/1998-9903-2018-20-3-4-3-10