POSSIBLE ERRORS OF CALCULATIONS OF LOSSES OF THE ELECTRIC POWER ON SHOP INDUSTRIAL NETWORKS

https://doi.org/10.30724/1998-9903-2018-20-11-12-81-92

Abstract

In the article it is devoted the analysis and researches of origins and values of possible errors from not accounting of the main defining characteristics when calculating losses of the electric power on shop networks of a low tension. It is proved that in case of determination of losses of the electric power in lines of shop networks it is necessary to consider influence of the following parameters of the equipment: the heating of conductors caused by passing of current of loading through conductors and ambient temperature; resistance of contact joints of switching devices and their number; type of the load graph; ambient temperatures. The diagram of a shop network and daily load graphs of customers of one of the enterprises is researched. Errors of calculations of losses of the electric power are calculated and the analysis of influence of parameters of the equipment on value of losses of the electric power is carried out. The absence of reliable information about elements of shop networks of a low tension and not accounting of the determining leads to an error 5 - 80% in case of computation of losses of the electric power in the systems of industrial electrical power supply.

About the Authors

E. I. Gracheva
Kazan state power-engineering university, Kazan
Russian Federation
Gracheva Elena Ivanovna – Grand PhD in Engineering sciences, Professor of the Department "Power Supply of industrial enterprises"



A. N. Alimova
Kazan state power-engineering university, Kazan
Russian Federation
Alimova Alsu Nurkhaydarovna – Masters Degree student of the Department "Power Supply of industrial enterprises"



References

1. Gruntovich N.V., Efremov L.G., Fedorov O.V. Enhancement of management systems energetic efficiency and economic safety of the industrial enterprises. //Bulletin of the Chuvash university. 2015. No. 3. P. 40–48.

2. Nemtsev A.G., Fedorov O.V., Shestakova L.A. About vibration of electromotors in the presence of the higher harmonic components in power supply tension // Works VIII international (the XIX All-Russian) conferences on the automated AEP-2014 electric drive in 2 volumes. 2014. P. 330–332.

3. Barinov V.A. Enhancement of standards of reliability of functioning of electrical power systems/V.A. Barinov, G.A. Voyakov, V.V. Kalita, F.L. Kogan, A.S. Manevich, V.V. Mogilev, F.I. Sinchugov, etc.//Electricity. 1993. No. 7. P. 17–23.

4. Kryukov O.V., Leonov V.P., Fedorov O.V. Application of microprocessor technique in the loading devices. // Engine building. 1987. No. 7.

5. Ryabchitsky M.V. Low-voltage switching (force) devices for needs of power industry / M.V. Ryabchitsky, D.N. Nechayev, A.V. Kokorin//Automation and IT in power engineering. 2014. No. 8 (61) P. 4–10.

6. Cooper N.F., Fedoseyeva A.V. Prediction of a power consumption of the industrial enterprise//Messenger of mining and metallurgical section of the Russian Academy of Natural Sciences. Separation of metallurgy. 2005. No. 15. P. 101–105.

7. Spiranovic A.A. Analysis of influence of probable parameters of an electric equipment on efficiency of functioning of systems of electrical power supply//Messages of higher education institutions of the Black Earth. 2013. No. 2. P. 25–32.

8. Spiranovic A.N., Spiranovic A.A. Assessment of efficiency of faultlessness. // Messages of higher education institutions of the Black Earth. 2013 No. 1. P. 25–33.

9. Spiranovic A.N., Spiranovic A.A.,. Kvashnina G.V. To assessment of parameters of faultlessness of the equipment of systems of electrical power supply//Messages of higher educational institutions of the Black Earth. 2016. No. 4. P. 48–56.

10. Stuffed cabbage N.V., Efremov L.G., Fedorov O.V. Problem of efficiency of use of energy resources///Bulletin of the Chuvash university. 2014. No. 2. P. 18–22.

11. Cockerels M.Yu., Sarvarov A. S., Fedorov O.V. totsenka of resource-saving of an electric equipment//Electric equipment: maintenance and repair. 2015. No. 3. P. 24–28.

12. Egorov A. N, Kuznetsov N. M., Fedorov O.V. Influence of the electric drive with the gated transformer on quality of electrical energy//Energy efficiency: experience, problems, decisions. 2010. No. 7. P. 21–23.

13. Sarvarov A. S., Shevyryov Yu.V., Fyodorov O.V. Assessment of efficiency of costs of increase in energetic indices on networks with semiconductor transformers//the Bulletin of the Southern Ural State University. Series: Power engineering. 2015. V. 15, No. 3. P. 11–19.

14. Yu-Lung L., Hong W., Jing-Gin C. Simulation and reliability analysis of shunt active power theory // Journal of Zhejiang University Science. 2007. №3. P. 416–421.

15. Ajami A., Hosseini S.H. Implementation of Novel Control Strategy for Shunt Active Filter // Ecti transactions on electrical eng., electronics and communications. 2006. №1. P.40–46.

16. Erickson R.W. Some Topologies of High Quality Rectifiers // First International Conference on Energy, Power and Motion Control. 1997. P. 1–6.

17. Graovac D., Katic V., Rufer A. Universal power quality system – an extension to universal power quality conditioner // international conference on power electronics and motion control. 2000. №4. P. 32–38.